Optional automation interface connections – Tweco CutMaster 101 with SL100SV User Manual
Page 167
Manual 0-4642
A-39
APPENDIX
A
6
6
7
7
8
8
9
9
10
10
A
B
C
D
E
F
DWG No:
Sheet
of
Supersedes
Scale
Date:
Drawn:
References
Date
By
Revisions
Rev
PCB No:
Assy No:
Information Proprietary to THERMAL DYNAMICS CORPORATION.
Not For Release, Reproduction, or Distribution without Written Consent.
NOTE:
Unless Otherwise Specified, Resistors are in Ohms 1/4W 5%.
Capacitors are in Microfarads (UF)
Chk:
App:
TITLE:
Last Modified:
Size
SCHEMATIC,
Thursday, March 24, 2005
1
1
11:05:29
DWG No:
Sheet
of
Supersedes
Scale
Date:
Drawn:
References
Date
By
Revisions
Rev
PCB No:
Assy No:
Information Proprietary to THERMAL DYNAMICS CORPORATION.
Not For Release, Reproduction, or Distribution without Written Consent.
NOTE:
Unless Otherwise Specified, Resistors are in Ohms 1/4W 5%.
Capacitors are in Microfarads (UF)
Chk:
App:
TITLE:
Last Modified:
Size
SCHEMATIC,
Thursday, March 24, 2005
1
1
11:05:29
DWG No:
Sheet
of
Supersedes
Scale
Date:
Drawn:
References
Date
By
Revisions
Rev
PCB No:
Assy No:
Information Proprietary to THERMAL DYNAMICS CORPORATION.
Not For Release, Reproduction, or Distribution without Written Consent.
NOTE:
Unless Otherwise Specified, Resistors are in Ohms 1/4W 5%.
Capacitors are in Microfarads (UF)
Chk:
App:
TITLE:
Last Modified:
Size
SCHEMATIC,
Thursday, March 24, 2005
1
1
11:05:29
THRU SCREW TERMINAL
PILOT
(E58)
19X1757
DC COM
(E62)
CHASSIS GND
(E35)
ISENSE
(14)
(15)
(17)
(18)
F1
COMP
DESCRIPTION
LOCATION
F2
SW1
SW2
FUSE, 1/4A 600V FNQ
FUSE, 0.9A, RESETABLE
M1
M2
FAN, 4.5" 220VAC
B2
B1
C1
PS1
PRESSURE SWITCH
SOL1
GAS SOLENOID
SWITCH, ON/OFF
SWITCH, RUN/SET/RAR
F4
F4
C1
C1
T5
D4
TS1
TS2
E1
D.Lilja
W1
MAIN CONTACTOR
F4
TEMP. SENSOR, IGBT HEATSINK
TEMP. SENSOR, INDUCTOR
CURRENT
L1
L1
OUTPUT INDUCTOR
D7
MAIN TRANSFORMER
DC COMMON
DC COMMON
+12VDC
J40
P40
WORK
T
O
R
C
H
OUTPUT INDUCTOR
NOTES: UNLESS OTHERWISE SPECIFIED -
1. DEPICTIONS OF CIRCUITRY INSIDE PCB BLOCKS
IS FOR REFERENCE ONLY
(REL)
DLL
SENSE
Vo
POWER OUTPUT BOARD ASSY 19X1914
CM81/101 600V 3PH SYSTEM
42X1134
D
AA
THERMAL DYNAMICS
INDUSTRIAL PARK No. 2
WEST LEBANON, NH 03784
603-298-5711
E49
E45
E62
E35
E43
E61
E3
E1
E58
E37
E36
E57
E63
J28
PILOT BOARD
8
5
PLUGS INTO J27
ON MAIN BOARD
*
4
5
8
2
3
1
6
7
3
5
4
6
7
8
2
1
5
3
7
6
4
8
2
1
CSR
JUMPER
E58
E62
E34A
E39A
E50A
E56A
E60A
E54A
E53A
E48A
E34B
E39B
E50B
E48B
E53B
E54B
E56B
E60B
ASSEMBLY
OUTPUT DIODE
19X1757
ASSEMBLY
OUTPUT DIODE
E64
(E64)
(E64)
F3
FAN, 4.5" 220VAC
D1
J2
J1
ALTERNATE 20-PIN HEADER
20-POSITION TERMINAL STRIP
5
4
3
5
4
6
1
7
2
3
8
6
7
19
13
10
16
14
9
15
12
11
18
17
18
17
19
20
13
10
16
14
9
15
12
11
8
2
1
20
J4
J3
4
5
2
3
8
1
6
7
4
5
8
3
2
7
1
OPTIONAL AUTOMATION INTERFACE CONNECTIONS
6
19X2041
TORCH SW -
TORCH SW +
DC COMMON
+12VDC
CSR
P1
OK TO MOVE
+
-
+
-
TORCH SWITCH
P3
3
2
1
1
2
3
Vo
DC
GAS
AC
TEMP
(LED PCB 19X1604)
J14 P14
7
1
6
3
2
8
4
5
1
5
8
4
6
7
2
3
5
4
6
1
7
2
3
8
18
17
19
20
13
10
16
14
9
15
12
11
P4
SC-11
+
-
DC COMMON
DIVIDED OUTPUT
REMOTE CURRENT CONTROL
C&G
CPC
HOUSING
4
14
3
12
6
5
8
9
7
OK TO MOVE
(+)
(-)
LOGIC COMMON
(+)
(-)
ARC VOLTS (C&G)
(+)
(-)
TORCH SWITCH
ASSY 19X2157
}
}
}
}
E32
ECO 101136
CSR
RAR OFF
3
(46)
(47)
(48)
(49)
(CSR)
(51)
(52)
(TS2)
(TS1)
(NEG)
(56)
(57)
(58)
(59)
(60)
(61)
(62)
(63)
(64)
2
1
2
1
J1
(52)
(51)
HAS
ECO 101314
AB
HAS
ECO 101429
AC
WHEN REMOTE CURRENT
CONTROL IS USED WITH
AUTOMATION
(REPLACES CONNECTIONS
FROM J27 TO J14)
ADAPTER HARNESS USED
05/07/03
02/11/04
05/07/03
06/09/04
OPTIONAL
AUTOMATION
INTERFACE
ATC MALE CONNECTOR
ATC RECEIVER
(MODE SW)
(C1)
(NEG)
(CSR)
ECO 101614
HAS
AD
03/22/05
AE
ECO 101664
HAS 03/24/05
A-06752