INSTALLATION
3
5.
Connect the wire harness from the alternate CNC Control to the 20-position terminal strip (labeled 'J2') on the Automation
Interface PC Board. Refer to the illustration.
a. For divided voltage output, connect to terminals J2-11 (negative) and J2-9 (positive) on the Interface PC Board..
b. For raw arc voltage, connect to terminals E2 (positive) and E1 (negative) on the Output Power PC Board.
NOTE
There is no need to disconnect the factory-installed wire harness from the J4 terminal strip.
3
9
5
4
1
2
6
7
8
10
13
19
15
14
11
12
16
17
18
20
Art # A-04149
To
rch Switch
(P
ositiv
e)
To
rch Switch (Ne
gativ
e)
OK to
Mo
ve
OK to Mo
ve
Divided
Outpu
t (P
ositiv
e)
Divided Outpu
t (Negativ
e)
Logic Commo
n
Open
Open
Open
Open
Open
Open
Open
Open Arc
Vo
lts - P
ositiv
e (Propr
ietar
y)
Arc
Vo
lts Negativ
e - (Propr
ietar
y)
Remote Current Cont
rol (Optional)
Remote Current Cont
rol (Optional)
Remote Current Cont
rol (Optional)
To Main PC Board
Terminal J27-3
To Main PC Board
Terminal J27-1
To Main PC Board
Terminal J27-2
Installed only with
Optional Remote Current Control
Terminal Block J2
E2 (+)
E1(-)
Automation Interface PC Board
Output Power PC Board
Raw Arc Voltage
Connection Points
Alternate CNC Controller Connections to Automation Interface Board
6.