Setting

Display

FLOOR HIGH
The highest recorded floor temperature measurement.
Touch the number and the ENTER key to reset.

Access Level: Installer, User

Range: -76 to 149°F
(-60.0 to 65.0°C)

Conditions: Sensor 1 or 2 is set to FLOR.

Default: Not applicable.

FLOOR LOW
The lowest recorded floor temperature measurement.
Touch the number and the ENTER key to reset.

Access Level: Installer, User

Range: -76 to 149°F
(-60.0 to 65.0°C)

Conditions: Sensor 1 or 2 is set to FLOR.

Default: Not applicable.

FILTER HOURS
The total number of hours the fan has been operating
since the air filter was last replaced. Touch the number
and the ENTER key to reset and clear the Change
Filter warning message.
Access Level: Installer, User

Range: 0000 to 9999 hours

Conditions: Always available.

Default: 0000 hours

HEAT Y HOURS
The total number of hours the heat pump has been
in heating operation. Touch the number and the
ENTER key to reset.
Access Level: Installer, User

Range: 0000 to 9999 hours

Conditions: Y RELAY is set to HP.

Default: 0000 hours

HEAT W HOURS
The total number of hours the first stage heat W has
been operated for heating. Touch the number and
the ENTER key to reset.
Access Level: Installer, User

Range: 0000 to 9999 hours

Conditions: W TERM is set to HRF1, HRF2, CONV,
COIL, FURN , BKUP or OTHR.

Default: 0000 hours

HEAT W2 HOURS
The total number of hours the second stage heat
W2 has been operating. Touch the number and the
ENTER key to reset.
Access Level: Installer, User

Range: 0000 to 9999 hours

Conditions: ACC RELAY is set to W2.

Default: 0000 hours

COOL Y HOURS
The total number of hours the air conditioner or
heat pump has been in cooling operation. Touch the
number and the ENTER key to reset.
Access Level: Installer, User

Range: 0000 to 9999 hours

Conditions: Y RELAY is set to AC or HP.

Default: 0000 hours