Error messages, Step nine before you leave – tekmar 371 House Control User Manual
Page 19

19
STEP NINE
BEFORE YOU LEAVE
• Install the wiring cover over the wiring chamber and secure it to the base with the two screws provided. Place the front cover on the
control and snap it into place. Install a lock if security is required.
• A sticker has been provided with the control. It is designed to be placed over the
Zone 1...Zone 5 words so that the zone names can
be written onto the control.
• Place this brochure, and all other brochures related to the installation, in the protective plastic bag supplied
with the control. Place the bag in a conspicuous location near the control for future reference.
• It is important to explain the operation of the control to the end user and to anyone else who may be operating
the system.
Error Messages
Whenever a fault is detected in any of the sensors and / or room temperature units (RTUs), the indicator lights will flash in specific ways
to indicate the location of the problem. For detailed Sensor and RTU testing instructions see Data Brochures D 074 and D 054.
Zone 4 /
Open
Zone 3
Zone 5 /
Close
Zone 1 /
Cooling
2
3
4
5
Bed
rm
Living
Rm
Laundry
Ba
se
m
1
Kitchen
Supply sensor short circuit
Supply sensor open circuit
RTU 1 short circuit
RTU 2 short circuit
RTU 3 short circuit
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Optimum Start / Stop
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Light off
Outdoor sensor short circuit
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Outdoor sensor open circuit
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
Minimum
Boiler
DHW
Demand
Maximum
Supply
Zo — in short circuit
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Boiler sensor short circuit
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Boiler sensor open circuit
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
WWSD
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Occupied
UnOccupied
Timer Active
Internal fault
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Light on continually
Light flashing
Setpoint
Demand
Setpoint
Demand
Setpoint
Demand
Setpoint
Demand
Setpoint
Demand
Setpoint
Demand
Setpoint
Demand
Setpoint
Demand
Setpoint
Demand
Setpoint
Demand
Maximum
Supply
Enclosure is overheated
Power
WWSD
Minimum
Boiler
DHW
Demand
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Setpoint
Demand
Setpoint
Demand
RTU 4 Temperature sensor open
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Setpoint
Demand
RTU 5 Temperature sensor open
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Setpoint
Demand
RTU 3 Temperature sensor open
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Setpoint
Demand
RTU 2 Temperature sensor open
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Setpoint
Demand
RTU 1 Temperature sensor open
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Setpoint
Demand
RTU 4 short circuit
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Setpoint
Demand
RTU 5 short circuit
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Setpoint
Demand
RTU 4, floating and boiler mode
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Setpoint
Demand
RTU 5, floating and boiler mode
Occupied
Optimum Start / Stop
UnOccupied
Timer Active
Power
WWSD
Minimum
Boiler
DHW
Demand
Maximum
Supply
Setpoint
Demand