Temperature Adjustment

n

1. Loosen locknut.
2. Turn on fixture and run water for at least two minutes to allow

supply temperature to stabilize.

3. Turn temperature stem counter-clockwise for hotter or

clockwise for colder outlet temperature.

4. Tighten locknut to prevent accidental or unauthorized

temperature adjustment.

5. Re-check outlet temperature.

Repair Kit

n

Motor Repair Kit: .................................................................... 480 270

1. Mark pipe as shown.

This is pipe insertion depth.

2. Clean pipe end.

1. Remove collet clip.

2. Depress collet.

3. Pull tubing from tailpiece .

3. If using PEX tubing, insert pipe stiff-

ener (provided) into end of pipe.

4. Push tubing into tailpiece up to mark.

5. Insert collet clip.

PEX tubing only

Pipe Stiffener

Tail Piece

Mark

Collet clip

Collet depressed

Quick-Connect Installation

n

TO CONNECT

TO DISCONNECT

1 in. (25.4mm)

PEX

PEX tubing only

Pipe Stiffener

Mark

Collet clip

Collet depressed

Collet

Collet clip

Collet

3

/

8

in.Pipe (9.5mm)

To Install

n

1. Installation should be in accordance with acceptable

plumbing practices. Flush all piping thoroughly before

installation. Installation and

field adjustment are the respon-

sibility of the installer.

2. Locate suitable place for the

tempering valve. Valve should

be accessible for service and

adjustment and as close to the

point-of-use as possible.

3. Connect hot and cold supplies

to valve and outlet of tempering valve to fixture (s) using

1

/

2

"

or

3

/

8

" compression connections. For Quick-Connect refer

to Quick-Connect installation section.

4. Turn on hot and cold water supplies. If any leaks are

observed, tighten connections as necessary to stop leaks

before proceeding.

5. Turn on fixture and allow water to flow for 2 minutes.

Measure water temperature at the outlet. If water is not at

desired temperature, adjust as necessary (see temperature

adjustment section). Maximum outlet temperature of 105°F

(41°C) is recommended.

Typical Installation

Warranty

n

The Seller warrants that the equipment manufactured by it and covered by this order or contract is free from defects in material and workmanship and, without

charge, equipment found to be defective in material or workmanship will be repaired, or at Seller’s option replaced F.O.B. original point of shipment, if written

notice of failure is received by Seller within one (1) year after date of shipment (unless specifically noted elsewhere), provided said equipment has been properly

installed, operated in accordance with the Seller’s instructions, and provided such defects are not due to abuse or decomposition by chemical or galvanic action.

ThiS expreSS warranTy iS in lieu OF and excludeS all OTher warranTieS, guaranTeeS, Or repreSenTaTiOnS, expreSS OF implied. There are

nO implied warranTieS OF merchanTaBiliTy Or OF FiTneSS FOr a parTicular purpOSe. The Seller assumes no responsibility for repairs made on the

Seller’s equipment unless done by the Seller’s authorized personnel, or by written authority from the Seller. The Seller makes no guarantee with respect to material

not manufactured by it.

USA:  Phone: 1.800.669.5430 • Fax 1.847. 229.0526 • www.powerscontrols.com

Canada:  Phone: 1.888.208.8927 • Fax 1.888.479.2887 • www.powerscontrols.ca

IS-P-e480 1336

EDP# 6512252

© 2013 Powers

A Watts Water Technologies Company

WARNING: This product contains chemicals known to the

State of California to cause cancer and birth defects or

other reproductive harm.

For more information: www.watts.com/prop65