FOTOGUARD

TROUBLESHOOTING

RECOMMENDED REPAIR KIT

Gasket and Disc

1. Water leak at stem and/or bonnet

227-338

Replacement

(Item 1 for models 4, 5, 6, and 7)

Includes items: 1, 2, 3A, 3B, 4A, & 8

2. Flow of water continues after mixer is turned off

Motor Replacement

3. Variable or untempered discharge temperature

(65-115°F) 227-339
Includes items: 2, 3, 3A, 3B, 7, & 8

Valve and Hot Water

4. Flow of water continues after mixer is turned off due to

227-340

Seat Replacement

worn to hot water seat (6)

(Models 5, 6, & 7)

5. Variable discharge temperature continues after

Includes items: 2, 4A, 5, 6, 7, & 8

replacement of motor (3)

Combination Seat

6. Flow of water continues after mixer is turned off and shutoff

227-351

Replacement Std. Cap.

disc (3B) and/or hot water seat (6) has been replaced

Includes items: 2, 4, 4A, & 8

High Capacity Kit

7. To increase capacity of mixer to 9.0 gpm @ 45 psi diff.

227-431 (Models 5, 6, & 7)

(0.57 l/s @ 310 kPa)

Includes items: 2, 4, 4A, 5, 6, & 8

Low Capacity Kit

8. To decrease capacity of mixer to 1.5 gpm @ 45 psi diff.

227-445 (Models 5, 6, & 7)

(0.061 l/s @ 310 kPa)

Includes items: 2, 4, 4A, 5, 6, & 8

For parts not covered above, refer to Technical Instruction Form MV440-2.

SERIES 440
FOTOGUARD
High Capacity

TROUBLESHOOTING

RECOMMENDED REPAIR KIT

Gasket and Disc

1. Water leak at stem and/or bonnet

225-357

Replacement

(Item 1 for models 4, 5, 6, and 7)

Includes items: 1, 2, 3, 4A, & 5A

2. Flow of water continues after mixer is turned off

Valve and Cylinder

3. Variable or untempered discharge temperature

225-393*

Replacement

(Lime deposits can be removed with the use of various

Includes items: 3, 5, 5A, & 6

commercially available products designed for this purpose.)

Motor Replacement

4. If items 5 and 6 are free of lime and free-moving and

225-395

discharge temperature is variable or untempered

Includes items: 3, 4, and 4A

For easy removal of piston cylinder (item 6), order special wrench, part no. 225-350.
For parts not covered above, refer to Technical Instruction Form MV440-2.
* The valve assembly (5) and cylinder (6) must both be replaced at the same time when using this kit.

Do not use the new valve with an old cylinder, or vice versa.

TROUBLESHOOTING AND REPAIR

To determine model number of Hydroguard, refer to nameplate on body assembly.

5