BridgeWave AR80 User Manual
Page 40

AR/GE/FE/U 80/80X Installation Manual
35
58000519 rev. D
Antennas aligned on side lobes
Repeat antenna alignment
procedure.
Radios set to different
polarizations
Verify that both radios are
mounted in the same
polarization. (see section 3.6)
Installed two high or two low
band radios in one link
Verify that one end of the link is
high and the other end is a low
band radio
Test cable not inserted into test
port on radio properly
Ensure test cable is completed
inserted into the test port of the
radio.
Make sure that you are using
correct RSL voltage table.
If table is for a different product,
consult the correct product
manual.
Low link quality voltage
Antennas are not aligned for
maximum RSL
Verify antenna alignment, use
instructions provided in sections
3.63.9
Auto calibration not successfully
completed
Repeat autocalibration
procedure.
Interference
This is unusual unless other
radios using the same spectrum
are colocated.
Check for possible interference
by turning off the radio at the
other end of the link and verify
the RSL voltage on the local
site drops below 0.2V .
Test cable not inserted into test
port on radio properly
Ensure test cable is completely
inserted into the test port of the
radio.
Cannot connect to radio
network management agent
Incorrect IP address
configuration on radio or PC
Verify Ethernet connections are
up, verify IP address, check for
IP address conflicts, clear ARP
cache on PC, and/or perform
hard reset on radio unit (see
NMS manual).
Management agent access is
blocked through one or more
interfaces
Verify management access
configuration on Setup t, and
change if necessary. Try
accessing agent through other
interfaces (fiber, copper, radio
link)