5 Connecting Network Equipment
The networking equipment that will be connected to the 80GHz System should be prechecked to
ensure it operates properly backtoback over a wired connection. Once this has been confirmed, it
will save troubleshooting steps if a traffic problem arises after the radio is installed and connected to
the network equipment.
The 1000BaseX interface is factory preconfigured for autonegotiation and flow control enabled.
Autonegotiation and flow control can be disabled via the NMS.
The 10/100BaseT interface ships from the factory with autonegotiation enabled, and cannot be
configured otherwise.
The radios support all standard Ethernet frame sizes, up to 1632
bytes for untagged or 802.1q VLANtagged frames.
5.1 Network Port Statistics
If the capability exists in the network equipment connected to the 80GHz System, verify the
following:
· Link integrity
· There are no receive errors on the link
· Network traffic is flowing in both directions
For configuring the radio’s Management Agent, please goto the NMS Manual. It can be found in
the product downloads section online;