BridgeWave AR80 User Manual
Page 33

AR/GE/FE/U 80/80X Installation Manual
28
58000519 rev. D
At this point, open the Status page from the unit’s NMS interface and ensure the Radio TX and RX
is operating at 1000 Mbps for both radios.
Click the refresh button a few times to ensure it is a good reading.
If all indicators are good, then go to the next steps. If not, then go
back to step 1 or contact BridgeWave Technical Support for
assistance.
5.
Go to Statistics page and reset the stats for each radio end.
6.
Perform a ping test. Open two command line windows and ping the local and remote
management agent. Factory default IPs are; 192.168.0.1 for lowband and 192.168.0.2 for
highband and perform a ping to both ends and wait a few minutes, ensure you are getting
responses from the local and remote management agents.
7.
Review statistics page results and ensure packets are being transmitted, received, and there
are no excessive error conditions.
8.
If all is performing well, you must now 'disable' the InstallationAuto Calibration option on
the Setup page of each radio.
3.10.2 Installation AutoCalibration Feature (AdaptRate™ models only):
This feature should be disabled only after the radio system has been completely installed and
calibrated as described above.
In the NMS ‘Setup’ screen, select Installation AutoCalibration to ‘Disable’ and press the ‘Submit
new Values button at the bottom of the screen
Figure 3.10.21:
Installation AutoCalibration Setting
(AUTO CALIBRATION FINISHED)