BridgeWave AR80 User Manual
Page 36

AR/GE/FE/U 80/80X Installation Manual
31
58000519 rev. D
3.3
3.0
2.0
1.7
0.3
NO
ERRORS
CORRECTED
ERRORS
UNCORRECTED
ERRORS
Correctable Errors Detected
Uncorrectable Errors Detected
Deframer Unlocked (Link Down)
0
0
Errors
Q
U
AL
V
o
lt
a
g
e
(
V
D
C
)
0.0
Figure 3.10.32: Quality Voltage Graph
· Quality Voltages between 3.0V and 3.3V indicate PRE and POST FEC errorfree wireless
link.
· Quality Voltages between 2.0V and 3.0V indicate a low rate of errors that the forward error
correction will correct. The lower the voltage, the more errors are being corrected.
· Quality Voltages between 0.3V and 1.7V indicate excessive PREFEC errors in the wireless
link, some of which cannot be corrected by the FEC. To indicate this change in error
performance, the quality voltage will drop from 2.0V to 1.7V in a single step.
· Quality Voltages below 0.3V indicate an unlocked deframer condition. This will be
recognized as a linkdown condition.