BridgeWave AR80 User Manual
Page 34

AR/GE/FE/U 80/80X Installation Manual
29
58000519 rev. D
Failure to ‘Disable’ the Installation AutoCalibration option can
trigger an inadvertent recalibration of the system, under certain
power failure conditions.
3.10.3 Forced ReCalibration
Option 1: Use the AutoCal function in the NMS ‘Maintenance screen. This function will store the
calibration values in nonvolatile memory.
Option 2: Enable “installation auto calibration” in the NMS and ‘Apply Settings'. Disconnect the
DC power and fiber optic cables from the radio. Power up the radio while the fiber is still
disconnected. The Auto Calibration will start as soon as the fiber optic cable is reconnected to the
radio terminal.
When a radio is power cycled with the fiber connected to network equipment, the radio will use the
calibration values stored in nonvolatile memory from the last successful autocalibration process
even if the enable AutoCal setting being set to ‘Enable’. The radio link will come up immediately.
When a radio has “Installation Auto Calibration” disabled, the radio will use the calibration values
stored in nonvolatile memory from the last successful autocalibration process, regardless of the
fiber interface connected to network equipment or not.
Should moving the link to a new location or realignment of the
link become necessary, the link must be recalibrated per the auto
calibration procedure described in Section 3.10.