Input Requirements for PNP Input Sensors
PNP Input Sensors: 24V dc (terminals S1s and S2s)
Input current min.: 3 mA Input current max.: 25 mA
Min. pulse time: 1 ms ON, 1 ms OFF
Max. IPM at Inputs S1s and S2s
30,000
Adjustable Setting Ranges (impulses/minute)
SSM-FM-11A10: 5…40 ipm, 35…340 ipm, 300…2,700 ipm, or 1,200…
10,500 ipm
SSM-FM-11A20: 10…80 ipm, 80…650 ipm, 600…5,300 ipm, 2,400…
20,000 ipm
Outputs
Standstill (under-speed) Output Response Time
See formula
Over-speed Output Response Time
SSM-FM-11A10: Range 5…10,500: tR = 700 ms typ.
SSM-FM-11A20: Range 10…20,000: tR = 350 ms typ.
Switching Capacity to AC 15
3A / 230V ac for N.O. contacts (per IEC/EN 60 947-5-1)
2A / 230V ac for N.C. contact (per IEC/EN 60 947-5-1)
Electrical Life (Switching cycles of the output contacts, resistive load)
350,000 cycles @ 920 VA
1,000,000 cycles @ 440 VA
2,000,000 cycles @ 250 VA
5,000,000 cycles @ 125 VA
Output Configuration
Outputs K1 & K2: two redundant (total of four) safety relay N.O. (forced-
guided) contacts—AgNi, gold flashed; one auxiliary N.C. contact—AgNi,
gold flashed
Contact ratings (all N.O. and N.C. output contacts): 2 normally open
(N.O.) output channels and 1 normally closed (N.C.) aux. output
Current Rating:
Thermal Current Ith: 4A
Mechanical Life: More than 50,000,000 operations
Power Ranges
Min. voltage: 15V ac/dc
Max. voltage: 230V ac/dc
Min. current: 30 mA ac/dc
Max. current: 4 A
Min. power: 0.45 W (0.45 VA)
Max. power: 100 W (920 VA)
NOTE: Transient suppression is recommended when switching inductive loads. Install suppressor across load. Never install suppressor
across output contacts (see Warning).
Certifications: Approvals are pending. This module was evaluated by UL to UL508 Industrial Control Equipment, which is not a certification relating to the safety perform-
ance of the module.
Dimensions
140782_web.
EC Declaration of Conformity
Date: 10/07/2009
We herewith declare that SSM-FM-11A10 and SSM-FM-11A20 Safe Speed Monitoring Modules for industrial control are in conformity with the provisions of the Machinery
Directive (Directive 98/37/EEC), and all essential Health and Safety Requirements have been met.
R. Eagle / Engineering Manager
Banner Engineering Corp. · 9714 Tenth Avenue North · Minneapolis, MN 55441-5019 USA
Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.
will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty
period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE,
COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSE-
QUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARIS-
ING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product
previously manufactured by Banner Engineering Corp.
SSM-FM-11A... Safe Speed Monitoring Modules