Optional Equipment
Directional Power Sensor (DPS)
The Bird 5010B and 5014 Thruline
®
Sensors require
two 43 or APM/DPM elements. The DPS measures both
forward and reverse power, so VSWR and other match
measurements can be calculated and displayed.
Note: The 5010B replaces the Bird 5010. The 5010 was
only compatible with APM/DPM elements, and lacked peak-reading
capability. The 5000-XT will still recognize the 5010.
Terminating Power Sensors (TPS)
The Bird 5011and 5015 series terminating power sen-
sors do not require elements. The Bird 5011 and 5015
have a frequency range of 40 MHz – 4 GHz. The 5011-
EF and 5015-EF sensors have a frequency range of 40
MHz – 12 GHz.
Wideband Power Sensor (WPS)
The Bird 5012B, 5016B, 5017B, 5018B, and 5019B Thrul-
ine Sensors do not require elements. The WPS can mea-
sure average, peak, or burst power, VSWR, crest factor,
and Complementary Cumulative Distribution Function
(CCDF).
Attenuators & Accessories
A variety of attenuators and connectors for measuring
large powers with the TPS. For a complete list, see
Soft Carry Case (P/N 5A5000-1)
Convenient and protective. Cutouts allow operation while in the case.