beautypg.com

Step 8: remove supply wires from fuse bases – Rockwell Automation 20D Balancing Resistor Kit - 690V Fr 13 PowerFlex 700AFE & Fr 13/14 PowerFlex 700H/S User Manual

Page 5

background image

Rockwell Automation Publication PFLEX-IN028A-EN-P - February 2012

5

Balancing Resistor Kit for 600/690V Frame 13 PowerFlex 700AFE and 600/690V Frame 13 and 14 PowerFlex 700H/700S AC Drives

Step 6: Remove Voltage

Feedback Board
Sheetmetal Cover
(if applicable)

See

Figure 9 on page 6

and remove the hardware fastening the voltage feedback

board sheetmetal cover (four M4 x 8 screws, use PZ2 – Head). Disconnect and
remove the connectors. Then remove the voltage feedback board.

Step 7: Unplug Main Fan

and Fan Inverter
Supply Connectors

Unplug the connectors shown in

Figure 6

that connect the main fan and fan

inverter supply.

Figure 6 - Unplugging Main Fan and Fan Inverter Supply Connectors

Step 8: Remove Supply

Wires from Fuse
Bases

See

Figure 7

and remove the supply wires and screws from the fuse sheetmetal

bracket. Remove the fuse bracket and insulation sheet (3 places).

Figure 7 - Removing Supply Wires from Fuse Bases

6 places
M4 x 8 screws
Tool: PZ2 – Head
Torque: 4 N•m

(2 per fuse bracket)

1. Document wire harness routing for reinstallation. Re-dress wire harness with ty-wrap as needed.
2. Be careful not to damage wire harness when removing and reinstalling the fuse brackets.
3. Route the wire harness before reinstalling the fuse brackets.
4. Ensure that fuse wires are black-to-black and red-to-red.