FactoryTalk Historian ActiveView User Guide
66
DisplayURLIsValid Property
This read-only, Boolean property indicates whether the specified location
of the FactoryTalk Historian ProcessBook display file is valid. If so, it
returns TRUE.
ReadyState Property
The read-only ReadyState property indicates the state of the control. The
possible states are:
State
Value
Description
pbReadyStateLoading
1
The control is being constructed. Once its
window is created, it becomes interactive.
pbReadyStateInteractive
3
FactoryTalk Historian ActiveView is loading
the display.
pbReadyStateComplete
4
The display is viewable.
These state transitions trigger the ReadyStateChange stock event.
Developers must use the integer values for these constants or to define them
within scripts. You can also look up these values in the Visual Basic Object
Browser.
ServerIniURL Property
The ServerIniURL property, which is optional, specifies the location of a
pilogin.ini file that contains Historian Server information.
This property also supports relative paths; however the first time the
control's ServerIniURL property is set, you must specify the absolute path.
After that, you may specify a ServerIniURL that is relative to the initial
path. The protocol may or may not be specified in the relative path. Note
that specifying a different protocol in the relative path is invalid. Also, the
property always returns the absolute path.