Industrial Performance Monitors 11

Rockwell Automation Publication 6186M-IN002C-EN-P - December 2011

The

surrounding air temperature must not exceed the maximum operating temperature.

Consider heat produced by other devices in the enclosure. You may need a user-supplied
fan, heat exchanger, or air conditioner to meet this condition.

The humidity of the surrounding air must not exceed specified limits. In dry
environments, static charges build up readily. Proper grounding of the equipment
through the AC power cord helps to reduce static discharges, which may cause shocks
and damage electronic components.

The enclosure or cover must remain in place at all times during operation. The cover
provides protection against high voltages inside the product and inhibits
radio-frequency emissions that might interfere with other equipment.

When mounted, the product cannot be tilted more than 60° from vertical.

TIP

Hot air rises. The temperature at the top of the enclosure is often higher than the temperature
in other parts of the enclosure, especially if air is not circulating.

IMPORTANT

The product can operate at a range of extremes. However, the life span of any electronic device
is shortened if you continuously operate the product at its highest rated temperature.

ATTENTION: Industrial computers and monitors are not safety devices. Standard safety
practice and redundancy should be followed in the application of this product.

≤60°
from vertical

≤60°
from vertical