Defining Command and Status Blocks
Chapter 3
3-14
The following table helps you identify:
acronyms of various command and status blocks that your ladder logic
transfers to and from the SPI module
SPI-specified ID codes of devices that you can place on the SPI network
Table 3.N
Standard Device Types with ID Code, and Acronyms for Command and Status Blocks
Type of
Command or Status Block
ID Code
HEX Binary
Block Acronym
Command Status
SPIĆspecified Module Configuration Command
FF 11111111
MCC
SPIĆspecified System Status
FF 11111111
SYS
Custom Configuration Block
Select the SPIĆspecified
device type ID from the
CCB
Custom Configuration Status
deviceĆtype ID from the
ID codes listing below.
Allowable range is
CCS
Custom Data Block
Allowable range is
20ĆFE.
CDB
Custom Data Status
CDS
Type of Device
ID Code
HEX Binary
Block Acronym
Command Status
Mold Temperature Controller
20 00100000
MTC
MTS
Chiller
21 00100001
CHC
CHS
Dryer
22 00100010
DRC
DRS
Loader
23 00100011
LDC
LDS
Melt Pump
24 00100100
MPC
MPS
Additive Feeder
25 00100101
AFC
AFS
SelfĆtuning Temperature Controller (Hot Runner)
26 00100110
STC
STS
GeneralĆpurpose Temperature Controller
27 00100111
GPC
GPS
Volumetric Blender
28 00101000
BVC
BVS
ContinuousĆweigh Blender
29 00101001
BCW
BCS
BatchĆweigh Blender
2A 00101010
BBW
BBS
Robot
2B 00101011
?
?
Summary of SPI
Block Acronyms,
Device Types,
and ID Codes