European Hazardous Location Approval

WARNING: This equipment is intended for use in potentially
explosive atmospheres as defined by European Union Directive
94/9/EC and has been found to comply with the Essential Health
and Safety Requirements relating to the design and construction
of Category 3 equipment intended for use in Zone 2 potentially
explosive atmospheres, given in Annex II to this Directive.

Compliance with the Essential Health and Safety Requirements has
been assured by compliance with EN 60079-15 and EN 60079-0.

WARNING:

This equipment is not resistant to sunlight or other sources of UV
radiation.

This equipment must be installed in an enclosure providing at
least IP54 protection when applied in Zone 2 environments.

This equipment shall be used within its specified ratings defined
by Rockwell Automation.

Provision shall be made to prevent the rated voltage from being
exceeded by transient disturbances of more than 40% when
applied in Zone 2 environments.

Secure any external connections that mate to this equipment by
using screws, sliding latches, threaded connectors, or other
means provided with this product.

Do not disconnect equipment unless power has been removed or
the area is known to be nonhazardous.