European hazardous location approval – Rockwell Automation 1783-US08T Stratix 2000 Ethernet Unmanaged Switch Installation Instructions User Manual
Page 4
4 Stratix 2000 Ethernet Unmanaged Switches
Rockwell Automation Publication 1783-IN001D-EN-P - January 2011
European Hazardous Location Approval
WARNING: This equipment is intended for use in potentially
explosive atmospheres as defined by European Union Directive
94/9/EC and has been found to comply with the Essential Health
and Safety Requirements relating to the design and construction
of Category 3 equipment intended for use in Zone 2 potentially
explosive atmospheres, given in Annex II to this Directive.
Compliance with the Essential Health and Safety Requirements has
been assured by compliance with EN 60079-15 and EN 60079-0.
WARNING:
•
This equipment is not resistant to sunlight or other sources of UV
radiation.
•
This equipment must be installed in an enclosure providing at
least IP54 protection when applied in Zone 2 environments.
•
This equipment shall be used within its specified ratings defined
by Rockwell Automation.
•
Provision shall be made to prevent the rated voltage from being
exceeded by transient disturbances of more than 40% when
applied in Zone 2 environments.
•
Secure any external connections that mate to this equipment by
using screws, sliding latches, threaded connectors, or other
means provided with this product.
•
Do not disconnect equipment unless power has been removed or
the area is known to be nonhazardous.