beautypg.com

Rockwell Automation 1783-US08T Stratix 2000 Ethernet Unmanaged Switch Installation Instructions User Manual

Page 14

background image

14 Stratix 2000 Ethernet Unmanaged Switches

Rockwell Automation Publication 1783-IN001D-EN-P - January 2011

5.

If the connector is not already installed in the switch, wire the connector
before replacing it in the switch.

6.

Use the 3 mm (0.12 in.) screwdriver to loosen the screw terminals on the
connector.

7.

Connect one AC output (20V AC nominal) from the low-voltge AC
power supply to terminal 5 (~20) and tighten the screw.

8.

Connect the other AC output (20V AC nominal) from the low-voltge
AC power supply to terminal 6 (~20) and tighten the screw.

Item

Description

1

Screw terminal connection from low-voltge AC power
supply to switch

-

1