26 Stratix 2000 Ethernet Unmanaged Switches

Rockwell Automation Publication 1783-IN001D-EN-P - January 2011

Operating shock
IEC 60068-2-27 (Test Ea,

Unpackaged Shock)

15 g

Nonoperating shock
IEC 60068-2-27 (Test Ea,

Unpackaged Shock)

30 g

Emissions
CISPR 11

Group 1, Class A

ESD immunity
IEC 61000-4-2

1783-US06T01F:
4 kV contact discharges
8 kV air discharges
1783-US03T01F, 1783-US05T, 1783-US08T:
6 kV contact discharges
8 kV air discharges

Radiated RF immunity
IEC 61000-4-3

10V/m with 1 kHz sine-wave 80% AM from
80…2000 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz
1V/m with 1 kHz sine-wave 80% AM from
2000…2700 MHz

EFT/B immunity
IEC 61000-4-4

±2 kV at 5 kHz on power ports
±2 kV at 5 kHz on communication ports

Surge transient immunity
IEC 61000-4-5

±1 kV line-line(DM) and ±2 kV line-earth(CM) on power
ports
±2 kV line-earth(CM) on communication ports

Conducted RF immunity
IEC 61000-4-6

10V rms with 1 kHz sine-wave 80% AM from
150 kHz…80 MHz

Environmental Specifications - Stratix 2000 Switches

Attribute

1783-US03T01F, 1783-US06T01F, 1783-US05T,
1783-US08T