Change memory and interrupt resources -8 – Rockwell Automation 1784-PCD DeviceNet Communication Card User Manual
Page 88

10-8 Troubleshoot the Card
Publication 1784-IN029C-EN-P - June 2001
Change Memory and Interrupt Resources
If you experience difficulty in configuring the PCD card, you should change the
memory and interrupt resources.
To find the available resources in your system,
Select Start
⇒
Programs
⇒
Administrative Tools
⇒
Windows NT Diagnostics. If
no interrupts are available, you may need to disable another device.
If You Are using:
Change Resources by:
pure NT (no third-party plug-and-play
software)
using the PCD card configuration tool on the
Windows Control Panel
SystemSoft’s CardWizard third-party
plug-and-play software
using the PCD card configuration tool on the
Windows Control Panel
Unicore/Touchstone Software’s CardWare
third-party plug-and-play software
contacting Rockwell Automation Technical
Support for assistance
Phoenix/Softex’s Card Executive
third-party plug-and-play software
contacting Rockwell Automation Technical
Support for assistance
IMPORTANT
Windows NT diagnostics may not show all interrupts that are
in use. If you continue to have problems, try another IRQ.
Recommended IRQ values are 7, 9, 10, 11, 12, and 15.
IMPORTANT
After you change these resources, you must reboot your PC for
the changes to take effect.