Dimensions, Specifications – Rockwell Automation MV SMC Flex OEM Components User Manual
Page 19

Power Stack Installation
4-3
1503E-IN001E-EN-P – June 2013
Table 4.C – Power Stack Specifications
Description
180 A, 360 A, 600 A
Input Voltages
(50/60 Hz)
1000 volts AC, 3 phase, +10%, -15%
2300 volts AC, 3 phase, +10%, -15%
3300 volts AC, 3 phase, +10%, -15%
4160 volts AC, 3 phase, +10%, -15%
6900 volts AC, 3 phase, +10%, -15%
Ambient
Temperature
0°C to 40°C (32°F to 104°F)
Power Section
(for 3 phases)
6 SCR at 1000/2300 volts
12 SCR at 4160 volts
12 SCR at 3300 volts
18 SCR at 6900 volts
Repetitive Peak
Inverse Voltage Rating
1000 volts – 4500 PIV
3300/4160 volts – 13000 PIV
2400 volts – 6500 PIV
6900 volts – 19500 PIV
Thermal Capacity
600% of FLA, 10 seconds
450% of FLA, 30 seconds
dv/dt Protection
R.C. Snubber Network
Maximum Heat
Dissipation (kW)
Start or Stop Cycle (@ 450% FLA)
Continuous
180 A
360 A
600 A
0 to 2499 V
7
13
22
.25
2401 to 4799 V
14
26
44
.25
4800 to 7200 V
21
39
66
.25
Altitude
0 to 1000 m (0 to 3,300 ft.)
(See Controller Deratings Table A-1 in Appendix A)
Net Shipping Weight
(3 phases)
Rating
1000 / 2300 V
3300 / 4160 V
6900 V
180A / 360A
105 kg (231 lb)
113 kg (249 lb)
126 kg (278 lb)
600 A
132 kg (290 lb)
154 kg (339 lb)
170 kg (374 lb)
Refer to Table 4.A for acceptable input voltage ranges.
180 A and 360 A ratings only for 1000 V power stack
For other ambient ranges, refer to Factory.
Dimensions
Refer to Figures 4.2 through 4.7 for the dimensions of the power
stacks.
Specifications