Guardshield, Original instructions, Six-month inspection – Rockwell Automation 440L GuardShield PAC Type 4 Safety Light Curtain User Manual
Page 25: Cleaning, Date code

GuardShield™ PAC Safety Light Curtain Installation Instructions
23
Original instructions
Six-Month Inspection
Check the following items every six months or whenever a
machine setting was changed.
Cleaning
If the optic front cover of the GuardShield PAC is dirty, the outputs
of the GuardShield PAC may turn off. Take a clean, soft cloth and
rub without pressure. Do not apply aggressive, abrasive or
scratching cleansing agents, which might attack the surface.
1.
o
Machine stops or does not obstruct any safety function.
2.
o
The latest machine or connection modifications have
no effect on the control system.
3.
o
The outputs of the GuardShield PAC are properly
connected to the machine.
4.
o
The total response time of the machine is shorter than
the calculated value.
5.
o
Cables and plugs of the GuardShield PAC are in flawless
condition.
6.
o
Mounting brackets, caps and cables are tightly secured.
Date Code
Figure 4: Explanation of data code
Location of Manufacture
Year of Manufacturer
Week of Manufacturer
X
X*
XX
M or 4K
R
02
M represented Manchester, NH replaced by 4K for Monterrey, Mexico
* J=2004
K=2005
L=2006
M=2007
N=2008
P=2009
R=2010
S=2011
T=2010
U=2013
V=2014
W=2015
Y=2016
Z=2017
Ref No.
Part No.
Rev
Rev
Ser
GuardShield
TM
Response Time with Coding
Response Time w/o Coding
Protective Height
Range
# of Beams/Spacing
Degree of Protection
2 Exec
u
tive Dr. Chelm
s
ford MA. 01
8
24
Prod
u
ct of Mexico
97
8
-441-9500
Electro-
S
en
s
itive
Protective E
qu
ip.
19KP
440L
Bul/Type
R4A2500YD
A B
Ser
440L
Bul/Type
Part No.
R4A2500YD
A B
Ambient Temp
Power Consumption
Supply Voltage
Safety Parameters
Operating Instructions
J
u
n, 2010
PN-11790
7W max.
IP65
2/520mm
0.3-16m
500mm
<30ms
<20ms
-10.....+55C
24V DC +/-20%
PAC
Rockwell Automation
PLe/SIL CL3,SIL3
IEC61496/ EN I
S
O 1
38
49
EN62061/ IEC6150
8
Type 4/Cat.4
M
a
de in
AA00AA00