Installation

9

3. 4

Wiring

3.4.1

Display Version

The 836E is a DC voltage switch with two PNP outputs or a single PNP output with a
4…20 mA analog output. Both options feature an M12 (micro) connector.

Fig. 4: Bulletin 836E with two PNP switch outputs or one PNP output with 4…20 mA analog output.

3.4.2

Nondisplay Version

The nondisplay version is offered with 4…20 mA analog output.

+

+

Load 2

Load 1

12…30V dc

2

1

3

4

4... 20 mA

Load 2

12-30V dc

2

1

3

4

+

--

4...20 mA

12 … 30V
DC