7technical data, Technical data 28, 1 display version – Rockwell Automation 836E Solid-State Pressure Sensors User Manual
Page 28

Technical Data
28
7
Technical Data
7. 1
Display Version
7.1.1
Power Supply
Supply voltage
•
DC voltage version
12...30V DC
Current consumption
•
Without load < 60 mA, with reverse polarity protection
Power supply failure
•
Behavior in case of over voltage
The device works continuously without any damage up to 34V DC.
If the supply voltage is exceeded, the properties specified are no longer guaranteed.
•
Behavior in case of under voltage
If the supply voltage drops below the minimum value, the device switches off (status as if
not supplied with power = switch open).
7.1.2
Output
Switching capacity
•
Switch status ON: I
a
≤ 250 mA
•
Switch status OFF: I
a
≤ 1 mA
•
Switching cycles: > 10 000 000
•
Voltage drop PNP: ≤ 2V
•
Overload protection
Automatic load check of switching current; output is switched off in case of over current,
the switching current is tested again every 0.4 sec.; max. capacitance load: 14 μF at max.
supply voltage (without resistive load) max. period length: 0.5 sec.; min. t
on
: 40 μs
Load (analog output)
•
Max. (V
supply
− 6.5V)/0.022 A
Input PLC
•
Input resistance R
i
≤ 2 kΩ
Input current I
i
≥ 10 mA
Signal on alarm
•
Analog output
≤ 3.6 mA / last current value / ≥ 21.0 mA adjustable
(if setting ≥ 21.0 mA the output is ≥ 21.5 mA)
•
Signal outputs
In safe state (switch normally open)