Technical Data

28

7

Technical Data

7. 1

Display Version

7.1.1

Power Supply

Supply voltage

DC voltage version
12...30V DC

Current consumption

Without load < 60 mA, with reverse polarity protection

Power supply failure

Behavior in case of over voltage
The device works continuously without any damage up to 34V DC.
If the supply voltage is exceeded, the properties specified are no longer guaranteed.

Behavior in case of under voltage
If the supply voltage drops below the minimum value, the device switches off (status as if
not supplied with power = switch open).

7.1.2

Output

Switching capacity

Switch status ON: I

a

≤ 250 mA

Switch status OFF: I

a

≤ 1 mA

Switching cycles: > 10 000 000

Voltage drop PNP: ≤ 2V

Overload protection
Automatic load check of switching current; output is switched off in case of over current,
the switching current is tested again every 0.4 sec.; max. capacitance load: 14 μF at max.
supply voltage (without resistive load) max. period length: 0.5 sec.; min. t

on

: 40 μs

Load (analog output)

Max. (V

supply

− 6.5V)/0.022 A

Input PLC

Input resistance R

i

≤ 2 kΩ

Input current I

i

≥ 10 mA

Signal on alarm

Analog output

≤ 3.6 mA / last current value / ≥ 21.0 mA adjustable
(if setting ≥ 21.0 mA the output is ≥ 21.5 mA)

Signal outputs
In safe state (switch normally open)