beautypg.com

6troubleshooting, Troubleshooting 26, Error codes – Rockwell Automation 836E Solid-State Pressure Sensors User Manual

Page 26: 1 error and warning codes

background image

Troubleshooting

26

6

Troubleshooting

6. 1

Error and Warning Codes

If an error occurs in the electronics, the color of the status LED changes from green to red and
the display shows an error or warning code, as outlined below:

E-code for errors
In the event of an error message, the measured value is unreliable.

W-code for warnings
In the event of a warning, the measured value is still reliable.

Error Codes

Code

Explanation

E011

Device configuration faulty

E012

Error in measurement

E015

Device error (internal)

E019

Power supply has under voltage/over voltage

E020

Device error (internal)

E021

Device error (internal)

E022

USB supply voltage

E025

Switching contact 1 is not open, although it should be open

E026

Switching contact 2 is not open, although it should be open

E040

Device error (internal)

E042

Output current cannot be generated.
Possible cause: analog output not connected

E044

Excessive output current drift (±0.5 mA)