Rockwell Automation 22-COMM-B PowerFlex BACnet MS/TP Adapter User Manual
Page 43
![background image](/manuals/577230/43/background.png)
Using BACnet Objects
4-5
Ta
b
le
4.
A
B
A
Cnet
O
b
je
ct Des
cri
pt
io
ns and Sup
por
te
d
Dr
iv
es (Co
n
ti
n
u
ed
)
Obj
ect
Na
me
Use Thi
s Obj
ect
t
o
…
Comp
ati
b
le
P
o
werF
le
x Dri
ves
4
4M
40
400
BI
1
S
ta
rt
In
put
Read
the st
at
e of t
he Sta
rt I
nput
on th
e
dr
iv
e’
s I/
O ter
m
inal b
loc
k.
✔✔✔✔
BI
2
D
ir
Inpu
t
R
ead
the st
at
e of t
he Dir (Dir
ect
ion)
In
pu
t on t
he dr
iv
e’
s I
/O t
er
m
in
al
bl
oc
k.
✔✔✔✔
BI
3
D
igit
al
Inpu
t 1
R
ead
the st
at
e of Digita
l I
nput
1 o
n t
he
dr
iv
e’
s I
/O
te
rm
inal
bl
oc
k.
✔✔✔✔
BI
4
D
igit
al
Inpu
t 2
R
ead
the st
at
e of Digita
l I
nput
2 o
n t
he
dr
iv
e’
s I
/O
te
rm
inal
bl
oc
k.
✔✔✔✔
BI
5
D
igit
al
Inpu
t 3
R
ead
the st
at
e of Digita
l I
nput
3 o
n t
he
dr
iv
e’
s I
/O
te
rm
inal
bl
oc
k.
—
—
✔✔
BI
6
D
igit
al
Inpu
t 4
R
ead
the st
at
e of Digita
l I
nput
4 o
n t
he
dr
iv
e’
s I
/O
te
rm
inal
bl
oc
k.
—
—
✔✔
Binar
y
Ou
tp
ut (BO) Objects
B
O
0
D
ig
ita
l O
ut
put
C
m
d 1
R
ea
d/wr
ite the
state
of D
ig
ital O
utpu
t 1 on
the d
riv
e’
s I/O te
rm
ina
l b
loc
k. The
dr
iv
e must b
e co
nfigu
red to
acce
pt th
e v
alue o
f this o
utpu
t from the n
etwor
k.
T
his is d
one
b
y se
tting th
e f
ollo
win
g dr
iv
e par
am
et
er
:
•
P
ow
er
F
le
x 4/
40:
P055
- [
R
ela
y Ou
t Sel]
to
the
v
alu
e “
20”
(P
ar
am
Cont
ro
l)
•
P
owe
rF
le
x
4M
: t
221
-
[R
el
ay
Ou
t Sel
] t
o th
e v
alu
e “
11
”
(P
ar
am
Co
nt
ro
l)
•
P
ow
er
F
le
x
40
0: T0
55 - [R
ela
y Out
1 Sel] t
o
the v
alue
“
12”
(
P
ar
amC
ont
rol)
✔✔✔✔
B
O
1
D
ig
ita
l O
ut
put
C
m
d 2
R
ea
d/wr
ite the
state
of D
ig
ital O
utpu
t 2 on
the d
riv
e’
s I/O te
rm
ina
l b
loc
k. The
dr
iv
e must b
e co
nfigu
red to
acce
pt th
e v
alue o
f this o
utpu
t from the n
etwor
k.
T
his is d
one
b
y se
tting th
e f
ollo
win
g dr
iv
e par
am
et
er
:
•
P
ow
er
F
le
x 40
: P058
-
[O
pt
o
Out
1 S
el]
to
the
va
lue
“20”
(
P
ar
amCo
ntr
ol)
•
P
ow
er
F
le
x
40
0: T0
60 - [R
ela
y Out
2 Sel] t
o
the v
alue
“
12”
(
P
ar
amC
ont
rol)
——
✔✔
B
O
2
D
ig
ita
l O
ut
put
C
m
d 3
R
ea
d/wr
ite the
state
of D
ig
ital O
utpu
t 3 on
the d
riv
e’
s I/O te
rm
ina
l b
loc
k. The
dr
iv
e must b
e co
nfigu
red to
acce
pt th
e v
alue o
f this o
utpu
t from the n
etwor
k.
T
his is d
one
b
y se
tting th
e f
ollo
win
g dr
iv
e par
am
et
er
:
•
P
ow
er
F
le
x 40
: P061
-
[O
pt
o
Out
2 S
el]
to
the
va
lue
“20”
(
P
ar
amCo
ntr
ol)
•
P
ow
er
F
le
x
40
0: T0
65 - [Op
to
Out
Sel] to
the v
alue “
12”
(
P
ar
amC
ont
rol)
——
✔✔