beautypg.com

Figure 3.8 – Rockwell Automation 20L PowerFlex 700L Liquid-Cooled Adjustable Frequency AC Drive User Manual

Page 57

background image

Frame 3A and 3B Installation

3-9

PowerFlex 700L Frames 2, 3A, and 3B Liquid-Cooled AC Drives User Manual

Publication 20L-UM001E-EN-P

the pallet mounting brackets. For safety when removing the pallet mounting
brackets, place blocks under the hoisted cabinet (

Figure 3.9

). The blocks

provide a measure of safety while the six M12 screws are unfastened under
the cabinet to remove the pallet mounting brackets. After the complete drive
equipment is placed at its installation position, remove the lifting angles to
permit the installation of the vented top cover over the input filter bay.
Assembly instructions are provided with the vented top cover. If the
complete drive equipment must be moved for any reason, remove the vented
top cover, and then reinstall the lifting angles to hoist the cabinet.

Figure 3.8 Frame 3 Complete Drive Lifting Instructions

Drive lifting points: three front (shown), and three back (not shown).

Pallet mounting brackets: three front (shown), and three back (not shown).

203

(8.00)

Maximum

Dimensions are in

millimeters and (inches).

Blocks for safe removal of pallet mounting brackets.

Full depth of cabinet. (4) - Places

!

ATTENTION: To guard against possible personal injury and/or
equipment damage, block the cabinet while removing the pallet
mounting brackets.