Table 6.A Status Indications
HIM Indication
The LCD HIM also provides visual notification of a fault or alarm condition.
Item Name
Color
State
Description
➊
POWER
Green
Steady
Illuminates when power is applied to the drive.
➋
STS
(Status)
Green
Flashing
Drive ready, but not running and no faults are present.
Steady
Drive running, no faults are present.
Yellow
Flashing,
Drive Stopped
A type 2 alarm condition exists, the drive cannot be
started. Check parameter 211 [Drive Alarm 2].
Flashing,
Drive Running
An intermittent type 1 alarm condition is occurring.
Check parameter 211 [Drive Alarm 1].
Steady,
Drive Running
A continuous type 1 alarm condition exists.
Check parameter 211 [Drive Alarm 1].
Red
Flashing
Fault has occurred. Check [Fault x Code] or Fault Queue.
Steady
A non-resettable fault has occurred.
➌
PORT
See the 20-COMM-x
Communication Adapter
User Manual.
Status of DPI port internal communications (if present).
MOD
Status of communications module (when installed).
NET A
Status of network (if connected).
NET B
Status of secondary network (if connected).
Condition
Display
Drive is indicating a fault.
The LCD HIM immediately reports the fault condition by
displaying the following information:
• “Faulted” appears in the status line
• Fault number
• Fault name
• Time that has passed since fault occurred
Press Esc to regain HIM control.
Drive is indicating an alarm.
The LCD HIM immediately reports the alarm condition by
displaying the following information:
• Alarm name (Type 2 alarms only)
• Alarm bell graphic
F-> Faulted
Auto
0.0
Hz
Main Menu:
Diagnostics
Parameter
— Fault — F
5
OverVoltage
Time Since Fault
0000:23:52
F-> Power Loss
Auto
0.0
Hz
Main Menu:
Diagnostics
Parameter
Device Select