Dpi connections for frame 2 drives, Drive connection points, External door-mounted him connection (optional) – Rockwell Automation 20L PowerFlex 700L Liquid-Cooled Adjustable Frequency AC Drive User Manual
Page 48: Coolant loop connections, Dpi connections for frame 2 drives -22, Coolant loop connections -22

2-22
Frame 2 Installation
PowerFlex 700L Frames 2, 3A, and 3B Liquid-Cooled AC Drives User Manual
Publication 20L-UM001E-EN-P
DPI Connections for Frame
2 Drives
Drive Connection Points
The PowerFlex 700L Frame 2 drive provides a number of cable connection
points as shown in
. If an additional external HIM is required for
the application, the HIM can be connected to the DPI port on the bottom of
the drive. Only one additional external HIM device may be connected. The
use of two external HIM devices is not supported. If multiple external HIM
devices are required, then install a user-supplied splitter cable or splitter box.
Figure 2.19 Frame 2 Drive DPI Connection Points
External Door-Mounted HIM Connection (optional)
For a Frame 2 drive installed in a user-supplied enclosure, an optional
external door-mounted HIM may be connected as an alternative to the
external HIM option. The cable supplied with the door-mount HIM option
kit connects to the DPI port on the bottom of the drive (see
). For
additional installation information, see the instructions provided with the
door-mount HIM option kit.
Coolant Loop Connections
See
for details.
Bottom View
of Drive
External
HIM Option
External
DPI Cable
T/L3
S/L2
R/L1
Drive
HIM Option
➊
Communications
Adapter Option
➍
➎
Active
Converter
PCB
➋
➌
Item
Connector
Description
➊
DPI Port 1
HIM connection when installed in the drive.
➋
DPI Port 2
Cable connection for handheld and remote options.
➌
DPI Port 3 or 2
Splitter cable connection to DPI Port 2 provides additional port.
➍
DPI Port 5
Cable connection for communications adapter.
➎
DPI Port 6
Internal DPI connection to Active Converter pcb.