beautypg.com

Rockwell Automation 1336T FORCE to PowerFlex 700S Phase II Drive Conversion Guide User Manual

Page 56

background image

1336 FOR

CE™ T

o

P

ow

erF

lex® 700S

Ph

ase II A

C

Driv

e C

o

nv

ersion Guide

56

Co

ntr

ol

Me

tho

d

In

du

cti

on

Mo

to

r:

B

rushles

s Mot

or

:

Indir

ect

Self–

O

rga

niz

ed, Field–

O

rien

te

d

C

ont

rol,

Cu

rr

ent

–r

egu

la

ted

, sine co

ded PWM

w

ith

pr

og

ra

mma

bl

e c

ar

rie

r

fr

eq

uenc

y.

Indir

ect

Self-

O

rg

aniz

ed,

F

ie

ld

-Or

ient

ed

Con

tr

ol,

Cur

rent

-r

egu

la

te

d. Sine co

ded PWM

wit

h pr

og

ra

mmab

le car

rier

fr

equen

cy

.

Rat

in

gs app

ly

to all dr

iv

es

. Re

fe

r t

o

the

P

ow

erF

le

x® 70

0S - Phas

e II

Co

nt

rol Ref

er

ence

Man

ual

, p

ub

licat

ion PFLEX-

RM00

3, f

or

der

at

in

g g

uidelines

. Th

e d

riv

e c

an

be

sup

plie

d a

s

6 p

ulse

or

1

2 p

ulse

in a

c

onf

ig

ure

d

pac

kage

.

C

arr

ier

F

req

uenc

y

HP

Dr

iv

e Rating

Ca

rr

ier

F

req

uenc

y

1–604

kH

z

1–12

kHz

15

-2

502 kHz

1-

6

kH

z

300–5

002 kHz

1-4

k

H

z

600–6

501.

5 kHz

1-4

k

H

z

700–8

001 kHz

1-4

k

H

z

Dr

iv

e r

at

ing:

4

kH

z

Set

tings

: 2,

4, 6,

8

, 10 kHz

(6

k

H

z

is

fo

r

V/Hz

o

per

ati

on

o

nl

y)

Dr

iv

e r

at

ing:

2

kHz

Set

tin

gs:

2

, 4,

6,

8,

10

k

H

z

(6

kH

z is f

or V/

Hz oper

at

ion only)

Ou

tpu

t V

olta

ge Range

:

0 to

ra

te

d mo

to

r v

ol

ta

ge

0

to

r

at

ed

mot

or

v

olt

ag

e

Ou

tpu

t F

reque

ncy Ran

ge:

0

to 250 Hz.

0 –

400 Hz

0 – 400 Hz Not

e:

F

or

o

utp

ut

fr

equen

cies abo

ve 320

-

4

00 Hz

co

nsult

the

fact

or

y.

S

peed Con

tr

ol

Sp

eed

Reg

ulation

wit

hout

e

nco

der

feed

bac

k

1%

of

top

s

peed o

ver

a

40

:1 sp

eed r

ange

Speed

r

egu

la

tion

- wit

hout

fe

edba

ck

0.

1% of

base

s

peed

ac

ro

ss

120

:1

s

peed

range

120:

1 ope

rat

ing r

ange

50 r

ad/s

ec ban

dwidt

h

Spe

ed reg

ulat

ion

-

wit

ho

ut f

eedb

ac

k

0.

1% of bas

e spee

d acr

oss

1

20:

1

spee

d

rang

e

120

:1

op

er

at

ing

range

50 r

ad/

sec

ba

ndwidt

h

Sp

eed r

egulat

ion - with

e

ncod

er f

eed

bac

k

0.

00

1%

of

to

p spee

d

ov

er

a

100.

1 spee

d

ran

ge

Speed

r

egu

la

tion

- wit

h

fe

edba

ck

0.

001% of

ba

se spe

ed acr

os

s

120:

1 spee

d r

an

ge

1000

:1 op

er

at

ing r

ange

744 r

ad/

sec

ba

ndwidt

h

Spe

ed reg

ulat

ion

-

wit

h f

eedb

ac

k

0.

001

%

of

b

ase sp

eed ac

ros

s 120:

1 sp

eed r

ange

100

0:

1 o

per

ating

r

ang

e

300

r

ad/

sec

b

andwidt

h

To

rq

ue Regu

la

tion

Torq

ue Regulat

ion -

wit

hout

fe

edbac

k

+

/-

5% o

f r

ate

d mo

tor

to

rqu

e

Tor

que

Reg

ulation

-

w

ithou

t f

eedb

ac

k

+/-

5%,

6

00 r

ad

/s

ec ban

dwidt

h

Tor

que

Re

gulat

io

n - witho

ut

feed

bac

k

+/

-1

0%,

600

r

ad/

sec

b

andwidt

h

Tor

que

Reg

ulation

-

w

ith

feedba

ck

+/-

2%,

2

500

ra

d/

sec

ba

ndwidt

h

Tor

que

Re

gulat

io

n - with f

eed

bac

k

+/

-5

%

, 2500

r

ad/

sec

b

andwidt

h

Selec

tab

le Motor

Cont

rol:

F

ie

ld

Or

ient

ed

Con

tr

ol w

ith

and

wit

hout

a

fe

edbac

k

de

vi

ce

.

Field

Or

ien

te

d

Co

nt

rol with an

d

wit

hou

t a f

eedba

ck de

vice and

pe

rm

anent

magne

t mot

or co

ntr

ol

St

op M

ode

s:

Mu

ltiple

pr

og

ra

m

m

ab

le st

op modes

inc

lu

ding –

Ra

mp

, Coas

t and

Cu

rr

ent

Limit

Multiple pr

og

rammab

le st

op mode

s in

cluding – Ramp

, Co

ast

a

nd Cur

re

nt Limit

A

ccel

/Dec

el

Inde

pend

ent

ly

p

rog

ramma

ble a

cce

l and

d

ecel

times

adjust

ab

le fr

om 0 to

65

53.

5 in

0.

1 sec

ond

in

cr

em

en

ts.

In

depen

dent

ly pr

og

rammab

le acc

el

and dece

l t

ime

s adjust

ab

le f

rom 0 t

o

6553.

5 in

0.

1 se

cond

inc

re

m

ent

s.

S

-Cur

ve Time

A

djust

ab

le f

rom 0.

5 to

4.

0 se

cond

s

In

te

rm

itt

ent

Ov

er

load:

150% f

or 1 min

ute

200% of mot

or

r

at

in

g

fo

r 10 sec

s - up t

o in

ve

rt

er limit

110% Ov

er

load

capability

fo

r up to 1 min

ute

150% Ov

er

load

capability

fo

r up to 3 se

cond

s

C

urr

ent

Limit

Capab

ilit

y:

Pr

og

rammab

le

fr

om

200%

of

r

ate

d

outp

ut

c

urr

ent

In

depen

dent

Moto

ri

ng

and Rege

ner

ativ

e P

ow

er

Limit

s pr

og

rammab

le t

o 800% of

r

at

ed

out

put

c

ur

ren

t

E

le

ctr

on

ic

Mot

or

Ov

er

load

P

rot

ec

tion

Pr

og

rammab

le

Mot

or

Ov

er

load Pr

ote

ct

io

n

(I

2

T)

in

ve

stig

ate

d

by

UL to co

mply with NEC Ar

ticle

43

0

Pro

vide

s

class

10

motor o

ver

load

protection

acc

ording to

NEC

ar

tic

le 43

0 a

nd

moto

r

ov

er-temper

at

ure

protec

tion acc

ording to NEC

ar

tic

le

430.

126 (

A

) (

2).

UL 508C File E5927

2.

Ca

teg

or

y

S

peci

fi

ca

ti

on

1336 FORCE Dr

ive

P

o

werF

le

x 700

S

Ph

ase I

I Dri

ve Fr

ames 1-

6 (69

0V Dri

ve

fr

ames 5 & 6

o

nl

y)

P

o

w

er

Fl

ex

70

0S Phase

II

Dr

ive

F

rames

9 & up

This manual is related to the following products: