Frame to ac drive rating cross reference, 400v ac input (using 700s kw ratings values), 480v ac input (using 700s hp ratings values) – Rockwell Automation 1336T FORCE to PowerFlex 700S Phase II Drive Conversion Guide User Manual
Page 14
![background image](/manuals/577162/14/background.png)
1336 FORCE™ To PowerFlex® 700S Phase II AC Drive Conversion Guide
14
Frame to AC Drive Rating Cross Reference
400V AC Input (using 700S kW ratings values)
480V AC Input (using 700S HP ratings values)
ND kW
HD kW
ND Cont.
Output Amps 1336 Frame
PF 700S Frame
0.75
0.55
2.1
B
1
1.5
1.1
3.5
B
1
2.2
1.5
5.0
B
1
4.0
3.0
8.7
B
1
5.5
4.0
11.5
B
1
7.5
5.5
15.4
B
1
11
7.5
22
B
1
15
11
30
B
2
18.5
15
37
B
2
22
18.5
43
B
3
30
22
56
B, C
3
37
30
72
C
3
45
37
85
C
4
55
45
105
C, D
5
55
45
125
D
5
75
55
140
D
6
90
75
170
D, E
6
110
90
205
E
6
132
110
260
E
6
132
110
261
E
9
160
132
300
E
9
200
160
385
E
10
250
200
460
E, F, G
10
250
250
500
F, G
10
315
250
590
F, G
11
355
315
650
F, G
11
400
355
730
G
11
ND HP
HD HP
ND Cont.
Output Amps 1336 Frame PF 700S Frame
1
0.75
2.1
B
1
2
1.5
3.4
B
1
3
2
5.0
B
1
5
3
8.0
B
1
7.5
5
11
B
1
10
7.5
14
B
1
15
10
22
B
1
20
15
27
B
2
25
20
34
B
2
30
25
40
B, C
3
40
30
52
B, C
3
50
40
65
C
3
60
50
77
C
4
75
60
96
C, D
5
100
75
125
D
5
125
100
156
D
6
150
125
180
D, E
6
200
150
248
E
6
200
150
261
E
9
250
200
300
E
9
300
250
385
E
10
350
300
460
E, F, G
10
450
350
500
F, G
10
500
450
590
F, G
11
500
500
650
G
11
600
500
730
G
11
700
600
820
H
12
800
700
920
H
12