Rockwell Automation Publication 23P-UM001D-EN-P - July 2012
Chapter 3 Gate Amplifier Installation and Wiring
Gate Interface to Rockwell Automation Power Modules
Rockwell Automation power modules 356405-Cxx, 356406-Cxx and 356407-
Cxx do not contain gate couplers. The gate couplers are contained in a separate
unit called the Gate Coupler Assembly. The basic interface configuration is
shown in
Connection to Rockwell Automation Power Modules
Cables appear in the tables following the illustration below.
Figure 25 - Connection to Rockwell Automation Power Modules
Table 12 - Round Style Connector Forward Gate Cables
Additional lengths can be found on drawing 97305100.
Table 13 - Round Style Connector Reverse Gate Cables
Additional lengths can be found on drawing 97305300.
Table 14 - Output of Gate Coupler Assembly to SCR Gate Cable
To view drawing, 97329100, (an increased length cable may be added in the
future, it will appear on the drawing when available.)
Gate Amplifier
FWD GATES
REV GATES
(Drawing 97305100)
(Drawing 97305300)
SD3K-CBLFWDPMxxx
SD3K-CBLREVPMxxx
Gate Coupler Assembly
SD3K-GATMDLHIGH
(9732017* to view drawing)
Gate Coupler Assembly
SD3K-GATMDLHIGH
(9732017* to view drawing)
(Drawing 97329101)
SD3K-CBLCPLR072
(Make as short as possible.
Do not route with power leads.)
(Drawing 97329101)
SD3K-CBLCPLR072
(Make as short as possible.
Do not route with power leads.)
Terminal Block
(Mounted on
power module)
Terminal Block
(Mounted on
power module)
Power
Modules
FWD
Module
REV
Module
Catalog Number
Length
SD3K-CBLFWDPM060
5 Feet
SD3K-CBLFWDPM120
10 Feet
SD3K-CBLFWDPM180
15 Feet
SD3K-CBLFWDPM240
20 Feet
Catalog Number
Length
SD3K-CBLREVPM060
5 Feet
SD3K-CBLREVPM120
10 Feet
SD3K-CBLREVPM180
15 Feet
SD3K-CBLREVPM240
20 Feet
Catalog Number
Description
SD3K-CBLCPLR072
The cable is a twisted pair wire with "box" connectors on one end that plug
onto the Gate Coupler Boards that are in the Gate Coupler Assembly. The
opposite ends are "pig-tails" for connecting the power module gate input
terminal blocks. Use a second set of this cable type for an S6R
configuration. (Cut to desired length, as short as possible.) Do not route