Setting function 2.1 – Waldmann PULSE PIR version IV - with MFT, Typ II User Manual
Page 24

24
Operating Manual Light Control „PULSE HFMD / PULSE PIR - Vers. IV“
ENG
Loading setting level 2
Actuation
Display
Light bar LED 1 (dark green)
Parameterisation mode ON
Function 2.1
Sensitivity high
Light bar LED 1 (dark green)
Function 2.1
Changing the function from ON to OFF or vice versa
Setting function 2.1
LED changes from constantly lit
to flashing or vice versa:
- constant = Function ON
- flashing
= Function OFF
Loading the parameterisation mode
Press both keys again
for 5 seconds
Light bar LEDs 1+2
Level 2
Sensitivity high
Function for changing the sensitiv-
ity of the presence control.
By default, the function is set to
"ON", i.e., the presence has its
normal sensitivity (100%). Small
movements are also detected
within the detection range of the
sensor.
When the function is set to "OFF",
the presence sensor works with
reduced sensitivity (approx. 50%).
Small movements are no longer de-
tected within the detection range
of the sensor.
The function can only be changed
on
- Lights equipped with HFMD
sensor
Press both keys
for at least 10 seconds
n x
Press key I as often as
necessary for reaching
the desired value
Release both keys