Setting function 1.3, 2 x n x – Waldmann PULSE PIR version IV - with MFT, Typ II User Manual
Page 18
18
Operating Manual Light Control „PULSE HFMD / PULSE PIR - Vers. IV“
ENG
Loading setting level 1
Actuation
Display
Light bar LED 1 (dark green)
Parameterisation mode ON
Function 1.3
Burn-In function
Light bar LED 3 (yellow)
Function 1.3
Changing the function from ON to OFF or vice versa
Setting function 1.3
LED changes from constantly lit
to flashing or vice versa:
- constant = Function ON
- flashing
= Function OFF
Press key II twice
Loading the parameterisation mode
Release both keys
Light bar LED 1 (dark green)
Level 1
Press both keys
for at least 10 seconds
2 x
n x
Press key I as often as
necessary for reaching
the desired value
Burn-in function
Function for burning in the lamps
By default, the function is set ex
works to "OFF". When the burn-in
function is activated, the following
functions are disabled:
- Light control
- Presence function
- Dimming function
After 100 operating hours, the
function is automatically set to
"OFF" again, i.e., the light can now
be operated without restrictions.
The function can be changed on
- Lights equipped with HFMD
sensor