Loading setting level 1
Actuation
Display
Light bar LED 1 (dark green)
Parameterisation mode ON
Function 1.1
Light bar
Light bar LED 1 (dark green)
Function 1.1
Changing the function from ON to OFF or vice versa
Setting function 1.1
LED changes from constantly lit
to flashing or vice versa:
- constant = Function ON
- flashing
= Function OFF
Jump to function 1.1
takes place automatically
Light bar
Function for switching the light bar
on and off.
By default, the function is set to
“ON”. The light bar is on.
When the function is changed, the
light bar remains switched off in
normal operation.
The function can be changed on
- Lights equipped with HFMD
sensor
- Lights equipped with PIR sensor
- Dimmable lights
Note: In lights without column
operating unit, this function is not
active.
Loading the parameterisation mode
Release both keys
Light bar LED 1 (dark green)
Level 1
Press both keys
for at least 10 seconds
n x
Press key I as often as
necessary for reaching
the desired value