3.7

Door Slab Resizing

Door Slab Resizing Beyond Maximum Trimming Limits

Height Resizing

Note:

A standard door can be cut down to any size if it is aesthetically acceptable, the following

procedure for re-railing is followed, and it conforms to the applicable code requirements.

Flush doors and paneled doors may be re-railed. Any height re-sizing beyond maximum

trim limits requires rail replacement. 20-minute steel fire doors can only be resized by a

Warnock Hersey certified re-machiner.

Width Resizing

Doors cannot be edge-trimmed beyond the limits listed in SHOP 3 - Door Slab Trimming

Saw Slab to Length

Measure and mark door slab.

Cut along line with saw, using

carbide-tipped blade. If

available, use panel saw.

Touch up edges with rasp or

sandpaper.

Note: For 20-minute steel fire

doors, a maximum of 6” may be

removed from the bottom of

the door.

Mark for New Rail Pocket

Use new rail as a pattern.

Center rail against cut end

of door slab.

Scribe at rail ends to mark limits

of cut for rail pocket.

Equal

Equal

Scribe line

each end

STOP:

Fiberglass impact doors and 20-minute fiberglass fire doors cannot be re-sized

beyond maximum trimming limits. For 90-minute steel edge fire doors, see

90-minute fire door slab re-sizing section.