Site installation instructions for adjusta-fit, Adjusta-fit 2 prehanging instructions – Therma-Tru Doors Installation User Manual
Page 56
Installation
1.56
2014
SITE 1
Adjusta-Fit 2
Prehanging Instructions
CODES
Building codes may vary from area to area.
If a fire rating is required of the door and
opening being framed, the installer must
use installation materials and methods to
satisfy the authority having jurisdiction.
Therma-Tru provides labeled products,
but bears no responsibility for installation.
Read instructions carefully before
installing your new Therma-Tru
Adjusta-Fit
®
2 system.
all
Please note there are separate “Prehanging
Instructions” to be reviewed and followed
prior to completing the installation.
Site
Installation
Instructions
for
Adjusta-Fit
®
2
1750 Indian Wood Circle Maumee, Ohio 43537
1-800-THERMA-TRU (843-7628)
www.thermatru.com
Therma-Tru Positive Pressure
(NFPA-252/UL-10C/CAN4-S104)
Labeled Systems
© Copyright 2009 Therma-Tru Corp. All rights reserved. Therma-Tru Corp. is an
operating company of Fortune Brands, Inc. All trademarks are property of their
respective owners. 3/2009 Part # MSLCMFIST
This Therma-Tru door system has been labeled in
compliance with NFPA-252/UL-10C/CAN4-S104
Positive Pressure Smoke and Draft control rating and
requires a listed Category “H” gasket and the
application of an additional Category
edge
sealing system. To maintain the validity of this
certification, the door installer must follow these
instructions. They should be kept on file on the
building premises for verification by the authority
having jurisdiction.
Verify that the frame is compatible with the
door and properly installed.
Install hardware per the hardware
manufacturer's instructions.
For Positive Pressure Rating, a listed and
labeled category “G” edge seal shall be
installed into the opening.
For smoke rating, a listed and labeled
category “H” Smoke and Draft control
gasket (included) shall be installed into the
opening.
Installation must comply with requirements
of NFPA 80 “Standard for Fire Doors and
Fire Windows”.
Surface mounted hardware must be attached
with through bolts unless interior
“G”
•
•
•
•
•
•