TROUBLESHOOTING

Problem

Possible Cause

Solution

Locking
conditions

Reset the Proflame DFC board

· Turn the system off by pressing the ON/OFF button on the transmitter

· After approximately 2 seconds press the ON/OFF button on the

transmitter again.

· In the manual flame control mode, use the down arrow button to reduce

the flame to off, indicated by the word OFF displayed on the transmitter
LCD screen.

· Wait approximately 2 seconds and press the up arrow button, the

ignition sequence will start.

· With the transmitter off, move the slider switch on the receiver to the

OFF position.

· Wait approximately 2 seconds and move the receiver slider switch to the

ON position.

Main burners will
not start

The pilot flame has gone out

· See “Pilot will not remain lit”

The remote control is not working correctly

· Replace the batteries

The thermostat is disconnected or set too
high

· Set the thermostat to a lower temperature

Problem with thermopile circuit

· Check gas line pressure

· Check wiring to thermostat for breaks

· Check for flame impingement on thermopile

Flame lifting

Leak in vent pipe

· Check for leaks in vent connections

Improper vent configuration

· Check vent configuration with manual

Terminal may be re-circulating flue gases

· Check to see if terminal is on correctly

· May need to install high wind termination cap.

· Contact dealer

Blue Flames

The heater has just been started

· Normal during start up: flame will yellow as the fireplace heats up

Improper air shutter adjustment

· Adjust air shutter – contact your dealer

Glass fogs up

Normal condition: after the appliance warms
up the glass will be clear.

**Due to additives in gas, glass may get hazy during operation** Clean as
needed.

Flames are
burning “dirty” or
sooting

The logs or glasses are placed incorrectly

· Check log positioning

· Check level of glasses layout

Improper air shutter adjustment

· Increase primary air by opening the air shutter and/or by opening the

vent restrictor

· Check for proper venting and blockage of the vent termination

· See also “Burners will not remain lit”

Incorrect rating input

· Check manifold pressure and clock input rating for over-firing