Installation – Regency Liberty L965E Large Gas Fireplace User Manual
Page 17
![background image](/manuals/573816/17/background.png)
16
APPROVED VENT PARTS:
Table 3: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS).
Part Description
Simpson
Duravent
Security Chim.
American
Metal
Selkirk Int.
Metal-Fab
EXCELDirect
6” Pipe Length
58DVA-06
SV5L6
5D7
5DT-06
5D6
TC-5DL6
9” Pipe Length
58DVA-09
5DT-09
12” Pipe Length
58DVA-12
SV5L12
5D12
5DT-12
5D12
TC-5DL1
24” Pipe Length
58DVA-24
SV5L24
5D2
5DT-24
5D24
TC-5DL2
36” Pipe Length
58DVA-36
SV5L36
5D3
5DT-36
5D36
48” Pipe Length
58DVA-48
SV5L48
5D4
5DT-48
5D48
TC-5DL4
60” Pipe Length
58DVA-60
8 ½” Pipe Extension
58DVA-08A
SV5LA12(12”)
5D7A
5D12A
5DT-AJ12
5DAL
16” Pipe Extension
58DVA-16A
SV5LA24(24”)
5D16A
5D26A
Flexible Length, 36”
TC-5DLF
12” Adjustable Length
TC-5DLT
45° Elbow
58DVA-E45
SV5E45
5D45L
5DT-EL45
5D45L
TE-5DE45
90° Elbow
58DVA-E90
SV5E90
5D90L
5DT-EL90
5D90L
TE-5DE90
Roof Flashing
58DVA-F6
SV5F /
SV5FA / SV5FB
5DF12
5DT-AF6
5DT-AF12
5DF
XF-6EF / XF-6EFA
/XF-6EFB
Storm Collar
58DVA-SC
SV5FC
5DSC
5DT-SC
5DSC
TM-SC
Ceiling Firestop
58DVA-FS
SV5BF
5DFSP
5DT-FS
TM-5CS
Wall Firestop
58DVA-WFS
5DFS
Wall Thimble
58DVA-WT
SV5RMS
5DWT
5DT-WT
5DWT
TM-5WT
Horiz. Square
Termination
58DVA-HC-*
SV5CHC
5DHCS
5DT-HC
5DHT
TM-5HT/TM-5DHT
Horiz. Round Termination
5DHC
Horizontal Sconce
Termination
Vert. Termination, High
Wind
58DVA-VCH
SV5CGV
5DVC
5DT-VT
5DVT
Vinyl Siding Standoff
58DVA-VSS
SV5VS
5DHVS
5DT-VS
5DVS
TM-VSS
Flex Venting 5” and 8”
Duraflex
*Several color choices
IMPORTANT: This chart covers the major components for each of these manufacturers only. Refer to the manufacturers’ catalogue for further
details on roof flashings and other installation items
The L965E/HZ965E fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS “AMERIVENT DIRECT”, SIMPSON
DURAVENT TYPE GS PIPE FOR GAS STOVES. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM”, SELKIRK “DIRECT-
TEMP VENT SYSTEM”, and EXCELDIRECT “ICC“ kits are available for horizontal and vertical venting. When planning an installation, it will be
necessary to select the proper length of vent pipe for the particular requirements.
WARNING: Do not mix parts from different vent manufacturers’ systems.
EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure
Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable
and does not affect the Intertek WH listing of the appliance.
Regency L965E / HZ965E Gas Fireplace
17
INSTALLATION