SMART THERMOSTAT (TRANSMITTER OPERATION)

The Smart Thermostat function adjusts the flame height in accordance to the difference between
the set point temperature and the actual room temperatures. As the room temperature gets
closer to the set point the Smart Function will modulate the flame down. To activate this function,
press the Thermostat Key (until the word “SMART” appears to the right of the temperature bulb
graphic (Figure 106). To adjust the set temperature, press the Up or Down Arrow Keys until the
desired set temperature is displayed on the LCD screen of the Transmitter.

REMOTE FLAME CONTROL

The Proflame GTMFS has six (6) flame levels. With the system on, and the flame level at the
maximum in the appliance, pressing the Down Arrow Key once will reduce the flame height
by one step until the flame is turned off. The Up Arrow Key will increase the flame height each
time it is pressed. If the Up Arrow Key is pressed while the system is on but the flame is off,
the flame will come on in the high position (refer to Figure 107). A single “beep” will confirm
reception of the command.

REMOTE ACTUATED ACCENT LIGHTS

The L965E is shipped with two (2) firebox accent lights. They are connected to the auxiliary power outlet of the Proflame Fan Control Module. The
lights can be turned on or off using the Auxiliary function on your remote control. Press the Mode Key on the remote control until the Auxiliary
Function icon is highlighted. Pressing the Up or Down arrow keys will turn the accent lights on or off. A single “beep” will confirm the reception
of the command

Figure 109: Remote Control Displays Set

Temperature.

Figure 110: Remote Control’s Smart Flame Function.

Figure 111: Remote Control’s Flame Levels.

Regency L965E / HZ965E Gas Fireplace