M
ark
96aa S
erieS
S
anitary
a
ir
a
ugMented
P
reSSure
r
egulatorS
-3-
F
eatures
& b
eneFits
316 T-handle for easy
handling and minimum
setpoint adjustment
Teflon Seal Nut
Bolted bonnet for increased
safety and pressure/
temperature rating
Self-draining design with 20 Ra (SFV5)
mechanical and electropolished internals (in
this orientation)
No guiding in the
wetted area
Guiding above diaphragm
area, not in seat/orifice, to
eliminate metal-to-metal
particulate generation
316 Stainless Steel
spring housing
316 adjusting screw
With an airload the
balanced spring and
bushing assembly provides
excellent stability and
minimal droop
Lifetime
guarantee on
Jorlon
diaphragm
100% barstock
body and trim
Minimum Allowable Differential Pressure:
No
restrictions
Minimum Allowable Setpoint:
Equivalent to the
minimum spring rate set point:
• 3/4" – 1": 3 psi (0,2 bar)
• 1-1/2" – 2": 10 psi (0,69 bar)
3": 15 psi (1,03 bar)
s
peciFications
(c
on
'
t
)
Surface Finish:
Refer to MK96 data sheet
Minimum Allowable Differential Pressure:
No
restrictions
Note: Steriflow does not recommend using metal
seated trim on any service where the flow will be
deadheaded downstream of the pressure reducing
regulator. Use an appropriate Teflon, Jorlon, or Peek
soft seat for the trim instead.
Maximum Allowable Pressure Setpoint:
The
total of the spring setpoint and additional air pres-
sure cannot exceed:
• 3/4" – 1": 135 psi (9,3 bar)
• 1-1/2": 100 psi (6,9 bar)
• 2" – 3": 80 psi (5,5 bar)