beautypg.com

Steriflow Mark 96AA Series User Manual

Page 3

background image

M

ark

96aa S

erieS

S

anitary

a

ir

a

ugMented

P

reSSure

r

egulatorS

-3-

F

eatures

& b

eneFits

316 T-handle for easy

handling and minimum

setpoint adjustment

Teflon Seal Nut

Bolted bonnet for increased

safety and pressure/

temperature rating

Self-draining design with 20 Ra (SFV5)

mechanical and electropolished internals (in

this orientation)

No guiding in the

wetted area

Guiding above diaphragm

area, not in seat/orifice, to

eliminate metal-to-metal

particulate generation

316 Stainless Steel

spring housing

316 adjusting screw

With an airload the

balanced spring and

bushing assembly provides

excellent stability and

minimal droop

Lifetime

guarantee on

Jorlon

diaphragm

100% barstock

body and trim

Minimum Allowable Differential Pressure:

No

restrictions

Minimum Allowable Setpoint:

Equivalent to the

minimum spring rate set point:
• 3/4" – 1": 3 psi (0,2 bar)
• 1-1/2" – 2": 10 psi (0,69 bar)
3": 15 psi (1,03 bar)

s

peciFications

(c

on

'

t

)

Surface Finish:

Refer to MK96 data sheet

Minimum Allowable Differential Pressure:

No

restrictions

Note: Steriflow does not recommend using metal

seated trim on any service where the flow will be

deadheaded downstream of the pressure reducing

regulator. Use an appropriate Teflon, Jorlon, or Peek

soft seat for the trim instead.

Maximum Allowable Pressure Setpoint:

The

total of the spring setpoint and additional air pres-

sure cannot exceed:

• 3/4" – 1": 135 psi (9,3 bar)

• 1-1/2": 100 psi (6,9 bar)

• 2" – 3": 80 psi (5,5 bar)