Vertical seam – Metal Sales Vertical Seam Installation User Manual
Page 38
800.406.7387 • www.metalsales.us.com
© Metal Sales Manufacturing Corporation Subject to change without notice Effective Date 5/13
VERTICAL SEAM
38
b
ox
g
utter
o
ver
o
pen
f
ramIng
All Gutter Flashings must be installed prior to panel installation.
1. Install Box Gutter flashing back against substrate. To hold Box Gutter flashing in place, fasten to substrate with
#10-16 x 1" Pancake Head Drillers 4'-0" o.c.
2. Install Universal Gutter/Downspout Straps every 3'-0" of gutter length to substrate with #10-16 x 1" Pancake Head Drillers,
and fasten to Box Gutter with (1) Pop Rivet per Strap.
3. Install panel by fastening through with #12-14 x 1
1
/
4
" Self Driller XL screws (see pages 34-35 for panel installation).
4. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a bead
of Tube Sealant between the flashings and securing with pop rivets 2
1
/
2
" o.c.
Universal Gutter / Downspout Strap (3'-0" o.c.)
Double Bead Tape Sealant
Box Gutter
Vertical Seam Panel
1
/
8
" x
3
/
16
"Pop Rivet (every strap)
CAUTION
In locations where heavy
rainfall or severe ice and
snow may occur, Metal
Sales' standard gutters may
not be suitable for use.
Tube Sealant
#12-14 x 1
1
/
4
" SD XL (see below)
INSTALLATION NOTES
3
1
2
4
Vertical Seam Fastening Pattern
3:12 Slope
Minimum