Vertical seam – Metal Sales Vertical Seam Installation User Manual
Page 37
800.406.7387 • www.metalsales.us.com
© Metal Sales Manufacturing Corporation Subject to change without notice Effective Date 5/13
37
VERTICAL SEAM
e
xtended
e
ave
o
ver
o
pen
f
ramIng
All Eave flashings must be installed prior to panel installation.
1. Position and install Cleat to wall with appropriate fastener, 1'-0" o.c. Make sure cleat allows for proper Extended Eave
attachment.
2. Install Extended Eave flashing by sliding open hem onto Cleat and resting Extended Eave Flashing back against substrate.
Fasten to substrate with #10-16 x 1" Pancake Head Driller (4'-0" o.c.) to hold Extended Eave flashing in place during
installation.
3. Apply a row of Double Bead of Tape Sealant to the Extended Eave flashing.
4. Install panel by fastening through with #12-14 x 1
1
/
4
" Self Drillers XL Screws (see pages 34-35 for panel installation).
5. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a bead
of Tube Sealant between the flashings and securing with pop rivets 2
1
/
2
" o.c.
Extended Eave
Double Bead Tape Sealant
Cleat
Tube Sealant
Vertical Seam Panel
#10-16 x 1" PHD (1'-0" o.c.)
#12-14 x 1
1
/
4
" SD XL (see below)
CAUTION
Additional screws
may be required for
high snow loading
and steep slopes.
INSTALLATION NOTES
3
1
2
4
Vertical Seam Fastening Pattern
3:12 Slope
Minimum