1. Once panels have been installed, field cut the Vertical Seam Z-Closure (see page 47) to fit between the panel ribs.

2. Place a row of Double Bead Tape Sealant across panel and over each panel rib approximately 2" from panel end. Before

proceeding, make sure Z-Closure placement will accommodate Vented Ridge cover.

3. Install field cut Z-Closure (as shown on page 47).

4. Fasten Z-Closure through panel with #10-12 x 1" Pancake Head Woodscrews (4 per panel).

5. Apply a row of Double Bead Tape Sealant across top leg of Z-Closure filling any gaps or openings around panel ribs.

6. Install Vent Drip, Vent Material, and Offset Cleat, as shown above with #14-13 x 1

5

/

8

" Dekfast screws, 1'-0" o.c. and apply a

row of Double Bead Tape Sealant to the top leg of the Offset Cleat.

7. Install Vented Ridge Cover to Offset Cleat with

1

/

8

" Pop Rivets at 1'-0" o.c.

8. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a

bead of Tube Sealant between the flashings and securing with pop rivets 2

1

/

2

" o.c.

Double Bead Tape Sealant

1

/

8

x

3

/

16

" Pop Rivet (1'-0" o.c.)

Vertical Seam Clip

Tube Sealant

Vertical Seam Panel

#14-13 x 1

5

/

8

" Dekfast (1'-0" o.c.)

Vent Material

Offset Cleat

Double Bead Tape Sealant

Vented Ridge Cover

Vent Drip

Vertical Seam Z-Closure

CAUTION

Additional screws

may be required for

high snow loading

and steep slopes.

1"

INSTALLATION NOTES

Moisture Barrier (by others)

1:12 Slope

Minimum

over Solid

Substrate