NOTES: 1.
Section properties are calculated per
AISI 2007.
2.
Ixx and Sxx are ef
fective section properties for deflection and bending.
Section Properties
SECTION PROPERTIES
Panel Profile
Width
in
Grade
Gauge
Yield ksi
W
eight psf
Top in Compression
Bottom in Compression
Ixx in
4
/ft
Sxx in
3
/ft
Ixx in
4
/ft
Sxx in
3
/ft
Image II
12
80
26
80
0.99
0.0205
0.0225
0.021
1
0.0232
Image II
16
80
26
80
0.92
0.0158
0.0170
0.0165
0.0177
See also other documents in the category Metal Sales For Home:
- 1 Mini-Batten (66 pages)
- 1.25 Corrugated (45 pages)
- 5V-Crimp (14 pages)
- 7/8 Corrugated (16 pages)
- Classic Rib Installation (37 pages)
- Classic Rib Manual (16 pages)
- Clip-Loc Installation (68 pages)
- Clip-Loc Manual (22 pages)
- DECRA (6 pages)
- Delta Rib Manual (16 pages)
- IC72-Panel (16 pages)
- Image II Manual (20 pages)
- IMPower Series (23 pages)
- Magna-Loc Installation (85 pages)
- Magna-Loc Manual (28 pages)
- Maxi-Batten Manual (18 pages)
- Metal Roofing and Siding (22 pages)
- PBR-Panel (20 pages)
- PBU-Panel (18 pages)
- Pro-Loc I Manual (20 pages)
- Pro-Panel II Manual (16 pages)
- Residential (49 pages)
- Seam-Loc 24 Installation (66 pages)
- Seam-Loc 24 Manual (26 pages)
- Secondary Framing (53 pages)
- Snap-Loc 24 Installation (69 pages)
- Snap-Loc 24 Manual (22 pages)
- Soffit (10 pages)
- Span-Line 36A (11 pages)
- Stile Installation (54 pages)
- Stile Manual (18 pages)
- T10-A (18 pages)
- T11-A (26 pages)
- T13 (32 pages)
- T-Armor Series (80 pages)
- TL-17 (16 pages)
- Vertical Seam Installation (52 pages)
- Vertical Seam Manual (26 pages)
- V-Line 32 (18 pages)