Fastening Guide (Cont.)

Recommended Fastener Spacing (inches)

For Slopes 6:12 to 12:12

Wind Speed (mph)

Exposure Category

Roof Slope: 6:12 - 12:12

90B

Field

-14.6 psf

Edge

-17 psf

Corner

-17 psf

24

24

24

90C

Field

-18.8 psf

Edge

-21.9 psf

Corner

-21.9 psf

24

24

24

100B

Field

-18.8 psf

Edge

-21.9 psf

Corner

-21 psf

24

24

24

100C

Field

-23.2 psf

Edge

-27.1 psf

Corner

-27.1 psf

24

24

24

110B

Field

-21.8 psf

Edge

-25.5

Corner

-25.5

24

24

24

110C

Field

-28 psf

Edge

-32.8 psf

Corner

-32.8 psf

24

24

24

120B

Field

-25.9 psf

Edge

-30.3 psf

Corner

-30.3 psf

24

24

24

120C

Field

-33.3 psf

Edge

-39 psf

Corner

-39 psf

24

24

24

Zone 1 (Field)

Zone 3 (Corner)

Zone 2 (Edge)

a

a

Notes:

1. Fastener spacing is based on #8-18 x

3

/

4

" Truss Head Woodscrew

fastener in the nail strip attaching to

5

/

8

" plywood . 1/3 allowable

stress increase is not used.

2. Allowable spacing is based on an applied load determined using

ASCE 7-05 for the Wind Speeds. Wind Exposure Categories,

Roof area, Gable roof, Enclosed building, Topographic factor of 1,

Importance factor of 1 and mean roof height of 20'.

3. Allowable spacing is determined for wind suction using the

combination 0.6 DL + WL. Also considered is the appropriate

inward wind pressure, 20 psf live load and the weight of the panel.

Contact Metal Sales for use of other types of fasteners and substrates.