Lenze MC3000 Series User Manual
Page 7

13435743_EDBM301_v14 .0
3
2
MC3000 SPECIFICATIONS
Storage Temperature
-20° to 70° C
Ambient Operating Temperature
Chassis
-10° to 55° C
(With 2 .5, 6, and 8 kHz carrier,
Type 1 (IP 31)
-10° to 50° C
derate for higher carriers)
Type 4 (IP 65)
-10° to 40° C
Type 12 (IP 54)
-10° to 40° C
Ambient Humidity
Less than 95% (non-condensing)
Altitude
3300 feet (1000 m) above sea level
without derating
Input Line Voltages
240/120 Vac, 240/200 Vac,
480/400 Vac, and 590/480 Vac
Input Voltage Tolerance
+10%, -15%
Input Frequency Tolerance
48 to 62 Hz
Output Wave Form
Sine Coded PWM
Output Frequency
0-120 Hz
Carrier Frequency
2 .5 kHz to 14 kHz
Frequency Stability
+0 .00006% / °C
Service Factor
1 .00
Efficiency
> 97% throughout speed range
Power Factor (displacement)
> 0 .96
Overload Current Capacity
150% of output rating for 60 seconds
180% of output rating for 30 seconds
Speed Reference Follower
0-10 VDC, 4-20 mA
Control Voltage
15 VDC
Analog Outputs
0 - 10 VDC, or 2 - 10 VDC
Proportional to speed and load
Digital Outputs
Form C relay: 2 A at 28 VDC or 120 Vac
Open-collector outputs: 40 mA at 30 VDC