Technical data
Rated data
Operation with rated power (normal operation)
l
117
EDK82EV903 DE/EN/FR 5.1
Ambient conditions
Motor connection
Length of the motor cable
< 50 m
shielded
< 100 m
unshielded
For rated mains voltage and switching frequency
£ 8 kHz
without additional output filters.
For compliance with EMC regulations, the permissible cable
length may be different.
Mechanical
Vibration resistance
(9.81 m/s
2
= 1 g)
Germanischer Lloyd
5 ... 13.2 Hz
Amplitude ±1 mm 13.2 ... 100 Hz:
acceleration resistant up to 0.7 g
IEC/EN 60068−2−6
10 ... 57 Hz
Amplitude 0.075 mm 57 ... 150 Hz:
acceleration resistant up to 1 g
Mounting conditions
Mounting place
In the control cabinet
Mounting position
Vertical
Dimensions,
free spaces
^ Chapter "Mechanical installation"
Weights
^ Chapter "Technical data", "Operation at rated power" or
"Operation at increased rated power"
3.2
Rated data
3.2.1
Operation with rated power (normal operation)
Data for operation at rated mains voltage and switching frequency 8 kHz. Data and
restrictions for other switching frequencies see system manual.
Type
Power
Rated mains voltage
Mains current [A]
Output current [A] )
Mass [kg]
[kW]
without
with
I
r
I
max
(60 s)
1)
without
with
P
r
Mains choke/mains
filter
Mains filter
E82xV153K4B
2)
15
3/PE AC 400 V:
320 V −0 % ... 440 V +0 %
45 Hz −0 % ... 65 Hz +0 %
DC 565 V:
450 V −0 % ... 620 V +0 %
43.5
29
32
48
13.5
(E82CV... 13)
34
3)
E82xV223K4B
2)
22
−
42
47
70.5
15
(E82CV... 13)
E82xV303K4B
2)
30
−
55
59
89
15
34
E82xV453K4B
2)
45
−
80
89
134
36
60
E82xV553K4B
2)
55
−
100
110
165
38
66
E82xV753K4B
2)
75
−
135
150
225
59
112
E82xV903K4B
2)
90
−
165
171
221
59
112
E82xV153K4B
2)
15
3/PE AC 500 V:
400 V −0 % ... 550 V +0 %
45 Hz −0 % ... 65 Hz +0 %
DC 710 V:
565 V −0 % ... 775 V +0 %
43.5
29
32
48
13.5
(E82CV... 13)
34
3)
E82xV223K4B
2)
22
−
42
47
70.5
15
(E82CV... 13)
E82xV303K4B
2)
30
−
55
56
84
15
34
E82xV453K4B
2)
45
−
80
84
126
36
60
E82xV553K4B
2)
55
−
100
105
157
38
66
E82xV753K4B
2)
75
−
135
142
213
59
112
E82xV903K4B
2)
90
−
165
162
211
59
112
1)
Currents for periodic load change: 1 min overcurrent time with I
max
and 2 min base load time with 75 % I
r
2)
Operation only permitted with mains choke (
^ 143
3)
E82CV...: Mains filter separately