2 rated data, Rated data, Feldbus-baugruppe 2113 interbus – Lenze EMF2113IB User Manual
Page 31: Technical data rated data

Technical data
Rated data
7
Feldbus-Baugruppe 2113 INTERBUS
7.3
7.3.2
L
7.3-2
EDSIBS-1.0-06/2003
7.3.2
Rated data
Insulation voltages between
incoming bus
and ...
Rated insulation voltage
Type of insulation
•
Reference earth / PE
50 V AC
Mains isolation
•
External supply (terminal 39/59)
50 V AC
Mains isolation
•
Power stage
– 820X / 821X
270 V AC
Basic insulation
– 822X / 8200 vector
270 V AC
Double insulation
– 93XX
270 V AC
Double insulation
•
Control terminals
– 820X / 8200 vector
(with internal supply)
0 V AC
No mains isolation
– 8200 vector
(with external supply)
100 V AC
Basic insulation
– 821X
50 V AC
Mains isolation
– 822X
270 V AC
Basic insulation
– 93XX
270 V AC
Basic insulation
•
Outgoing bus (OUT)
50 V AC
Mains isolation
Insulation voltages between
outgoing bus and
...
Rated insulation voltage
Type of insulation
•
Earth reference / PE
50 V AC
Mains isolation
•
External supply (terminal 39/59)
0 V AC
No mains isolation
•
Power stage
– 820X / 821X
270 V AC
Basic insulation
– 822X / 8200 vector
270 V AC
Double insulation
– 93XX
270 V AC
Double insulation
•
Control terminals
– 820X / 8200 vector
(with internal supply)
0 V AC
No mains isolation
– 8200 vector
(with external supply)
100 V AC
Basic insulation
– 821X
50 V AC
Mains isolation
– 822X
270 V AC
Basic insulation
– 93XX
270 V AC
Basic insulation
•
Input bus (IN)
50 V AC
Mains isolation
Show/Hide Bookmarks